6.4.1. Input philosophy: select start time
(Variant A: time preselection after program selection
1.
Switch on appliance with ON/OFF key S1
Ä
Display LD1 with the ON/OFF key is lit.
Ä
Appliance is in the "prestart" mode.
Ä
All program keys and the "SZV" key are unlocked and can be selected.
Ä
After the program has been selected you can also select possibly available
options as far as they are permitted for the program.
2.
Select program by pressing the corresponding key.
Ä
In addition to the LD1 display the corresponding program LED and the run time
LED are lit. The run time to be expected is flashing in the display, all program-
corresponding PAA LEDs (except the "end" LED) are lit.
Ä
With alternative variants of equipment it is possible that only the run time to be
expected or only the PAA LEDs are flashing in the output area.
3./4. Actuate the start-time preselection key within 3 seconds.
Ä
Display LD1 with ON/OFF key, program LED and "SZV" LED are lit
Ä
Set start time is flashing in the display.
Ä
All program-corresponding PAA LEDs (except the "end" LED) are lit.
Ä
With alternative variants of equipment (see figure) it is possible that only the run
time to be expected or only the PAA LEDs are flashing in the output area.
Any additional key pressure causes the start time scrolling by 1 hour
1h - 2h - ... - 19h - indication of remaining run time (SZV=0h) - 1h - 2h - ...
5.
3 seconds after the last actuation of the "SZV" key the set start time gets active and
is running down
Ä
In addition to the LD1 display the corresponding program LED and "SZV" LED are
lit. The start time is lit in the display.
Start-time preselection gets only active when the door has been closed!
S1
Ein/Aus
LD1
S2
LD2
LD3
S3
S4
LD4
S5
LD5
LD6
S6
S7
LD7
S8
LD8
LD9
S9
S1
Ein/Aus
LD1
S2
LD2
S3
LD3
S4
LD4
S5
LD5
S6
LD6
S7
LD7
S8
LD8
S9
LD9
S10
LD10
LD11
LD12
S11
1.99
LD13
LD14
LD15
LD16
LD17
LD18
LD19
LD20
LD21
LD22
LD23
LD24
S10
LD10
LD11
LD12
S11
1.99
LD13
LD14
LD15
LD16
LD17
LD18
LD19
LD20
LD21
LD22
LD23
LD24
S1
On/Off
LD1
S2
LD2
LD3
S3
S4
LD4
S5
LD5
LD6
S6
S7
LD7
S8
LD8
LD9
S9
1.
LD5
1h
5.
S10
LD10
LD11
LD12
S11
LD13
LD14
LD15
LD16
LD17
LD18
LD19
LD20
LD21
LD22
LD23
LD24
LD1
start-time preselection running down.
per key pressure
+ 1 hour
LD1
S5
LD5
S6
Prog.time
124
2.
display flashing
PAA
Delay timer
LD1
LD5
Prog.time
1h
3.
display flashing
PAA
Delay timer
LD1
LD5
Prog.time
1h
4.
display flashing
PAA
Delay timer
Prog.time
Delay timer
aprox. 3 secunds
display flashing
Prog.time
Delay timer
2h
3h
19h
124
PAA
display flashing
Prog.time
Delay timer
display flashing
Prog.time
Delay timer
display flashing
Prog.time
Delay timer