background image

© Electrolux

Muggenhofer Straße 135

D-90429 Nürnberg

Germany

Fax +49 (0)911 323 1022

Spares Operation

Publ.-Nr.:

599 515 206

09.02

R.Kurzke

Ausgabe:

EN

SERVICE MANUAL

DISHWASHER

EDW 2000

Dishwasher

with

EDW 2000

with

Содержание Diva EDW 2000

Страница 1: ...ctrolux Muggenhofer Straße 135 D 90429 Nürnberg Germany Fax 49 0 911 323 1022 Spares Operation Publ Nr 599 515 206 09 02 R Kurzke Ausgabe EN SERVICE MANUAL DISHWASHER EDW 2000 Dishwasher with EDW 2000 with ...

Страница 2: ...rogram selection 22 6 4 1 Input philosophy Select start time A 23 6 4 2 Input philosophy Select start time B 24 6 5 Input philosophy Program run 25 6 6 Input philosophy Delete program 26 6 7 1 Input philosophy Alter program 27 6 7 2 Input philosophy Alter program 28 6 8 Input philosophy Interrupt program 29 6 9 1 Input philosophy Displays part 1 30 6 9 1 Input philosophy Displays part 2 31 6 10 Ov...

Страница 3: ...rs ÖKO FAVORIT Appliances with height adjustable feet Applianceswithheight adjustablefeet Plinthheightforappliances820mmhigh 100 175mm Plinthheightforappliances870mmhigh 150 230mm Build in dimensions for Built Under Dishwashers ÖKO FAVORIT Dimensions for Freestanding Dishwasher Height 85 cm Width 60 cm Depth 60 cm Height with worktop removed 82 cm Feet adjustment 1 cm ...

Страница 4: ...e auxiliary winding ist in circuit with a 3 mF capacitor A tacho generator is used for speed control There are three speeds for rinsing 2800 1 min 2200 1 min 1900 1 min 1700 1 min 1600 1 min Power output 50 W 3 3 Drain Pump The drain pump is driven by a synchronous motor Power output 26 W Pump rate 15 l min 3 4 Flow Heater The flow heater heats the water to the required temperature During the wash...

Страница 5: ...lots in the detergent dispenser cover During the washing cycle the coil is switched on and the detergent compartment cover releases the detergent The rinse aid flows from compartment 1 into compartment 2 After switching off the coil the rinse aid flows from compartment 2 into compartment 3 During the rinse cycle the coil will be switched on when the rinse is warmed and the rinse aid runs from comp...

Страница 6: ...he base For a clear water the output voltage must always be 4 3 V If that value differsduetosoilingoftheturbiditysensorafteralongeroperational period the Easytronic plus recontrols the input voltage with the turbidity sensor automatically until the output voltage is 4 3 V This happens during the final rinse cycle If the 4 3 V is not achieved within 8 seconds the fault C5 is stored in the fault mem...

Страница 7: ...ing The new drying fan is located at the top on the rinse tank Celling spray arm upper spray arm lower spray arm Active Drying Active Drying means the ventilation of a container without any movable parts A plastic container is clipped into the opening in the container cover from where a hose is passed to the appliance base Function A small quantity of moist air and some condensate emerge from the ...

Страница 8: ...ds the softener is washed out with fresh water and is now fully effective Dependingonthewaterhardness regenerationisonlynecessary after several wash cycles Theremaining15 ofwaterflowthroughtherinsetankventilation directly into the appliance From setting of level 6 the whole water flows through the softener For this purpose you also have to set mechanically from 0 to 1 with the regenerating dosing ...

Страница 9: ...ction to remove the plate Abb 2 1 2 1 2 3 1 2 To remove side panel remove fixing screws pull the panel away from the rear and gently out of the front trim pic 1 Removing the cover plates of the base area remove these screwst Abb1 2 Remove the screws 1 to pull the outer door away To remove the panel remove the fixing screws 2 You need Torx epuipment ...

Страница 10: ...p 6 Pressure switch 7 4 5 6 7 Electronic input 1 and electronic display 2 are clipsed Elektronik power 3 in the bottom area 1 2 3 4 2 Position of Components Detergent dispenser 1 Spray arms 2 Roof mounted shower 3 Salt container 4 Filter 5 Type plate 6 1 2 3 4 5 6 ...

Страница 11: ...dosage chamber disengage locking tabs 1 disconnect hoses 2 holding the top of the chamber pull upwards disengaging it from the softener Removing the softener unit remove the securing nut located under the salt cap press softener 1 down and remove it through the front from the base area CAUTION if accessible release reed switch 1 2 3 4 5 1 2 1 ...

Страница 12: ... clips with a screwdriver figure take off base carefully and release circulation pump electronic and heater relay disconnect the float switch 1 2 3 4 5 With base removed following components are accessible Drain pump 1 Circulation pump 2 Flow heater 3 Temperature sensor Turbidity sensor 4 Pressure switch 5 ...

Страница 13: ...iner 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose 13 Base tray 14 Float switch 15 Pressure switch 16 Filter 17 Circulation pump 18 Flow heater 19 Drain pump 20 Non return valve 21 Spray arms 22 Roof mounted shower 23 Tub vent 24 Sump assembly 5 Water Course Scheme ohne Sicherheitszulaufschlauch Ausführung KurzeRegenerierdosierung 2 3 22 21 21 24 23 7 1 12 6 5 8 10 ...

Страница 14: ...illling the safety pressure switch starts the drain pump The water is only drained until it has reached the normal level because the reset point of the safety pressure switch is above the switchpoint of the normal pressure switch Leakage Protection The anti flood switch in the base tray will activate the drain pump and drain the water from the tub in the event of an internal leakage If the float s...

Страница 15: ...p operates the pressure switch 15 1 Inlet valve 2 Air break 3 Regeneration water dosage 4 Overflow safety level 5 Safety overflow 6 Inlet to sump from regeneration dosage chamber 7 Regeneration dosage chamber 8 Softener 9 Salt container 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose 13 Base tray 14 Float switch 15 Pressure switch 16 Filter 17 Circulation pump 18 Flow...

Страница 16: ...ached within total 4 minutes Timeout 2 the dynamic filling can be repeated 3 times Only after non successful repeating 3 times a failure code is displayed and the program is stopped The PPD LED LD9 is blinking LD9 LD10 LD11 LD9 LD10 LD11 The target speed is dependent on the subsequent pulse wash T imeout 1 T imeout 2 static water load to level dynamic water load with level control max 4 repetition...

Страница 17: ...ed to the circulation pump Function of the new pulse wash with random functionality After the filling steps the circulation pump is running at two rotational speeds The ratio of pulse time and pause is always 1 5 T high r T high T r T low T high r Ratio water in L 0 20 Sec start routine time in sec pressure switch point water level dynamic pulse wash level speed in U min 0 time in sec 2800 variabl...

Страница 18: ...e water 1 Inlet valve 2 Air break 3 Regeneration water dosage 4 Overflow safety level 5 Safety overflow 6 Inlet to sump from regeneration dosage chamber 7 Regeneration dosage chamber 8 Softener 9 Salt container 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose 13 Base tray 14 Float switch 15 Pressure switch 16 Filter 17 Circulation pump 18 Flow heater 19 Drain pump 20 N...

Страница 19: ...WKH ZDVK F FOHV VHF VHF VHF New draining with sequence draining The draining step contains of 3 time sequences In the middle sequence during time T2 the drain pump is stopped At the end of the drain step the water level is checked If the switch back is reached the drain step is terminated If the switch back isn t reached the drain step is repeated A failure code is displayed if after 2 drain steps...

Страница 20: ...5 LD5 LD6 S6 S7 LD7 S8 LD8 LD9 S9 S1 Ein Aus LD1 S2 LD2 S3 LD3 S4 LD4 S5 LD5 S6 LD6 S7 LD7 S8 LD8 S9 LD9 S10 LD10 LD11 LD12 S11 1 99 LD13 LD14 LD15 LD16 LD17 LD18 LD19 LD20 LD21 LD22 LD23 LD24 S10 LD10 LD11 LD12 S11 1 99 LD13 LD14 LD15 LD16 LD17 LD18 LD19 LD20 LD21 LD22 LD23 LD24 vertical key arrangement horizontal key arrangement Variant 1 maximum equipment S1 Ein Aus LD1 S2 LD2 LD3 S3 S4 LD4 S5 ...

Страница 21: ...opment Department in order to react to possibly coming design variants Positively necessary minimum equipment You always need besides key S1 ON OFF at least 3 program or option keys with pertinent LEDs in order to select all customer or service functions e g adjustment of hardness range You also absolutely need for output the display or the End LED l Functions which can be adjusted variably by the...

Страница 22: ...ese 3 seconds it is still possible to select a start time see description page B 4 Input philosophy start time preselection 4 Program is running Ä Corresponding program LED is lit Ä If available depending on variant the run time is indicated in the display the run time LED is lit Ä With alternative equipment variants it is also possible that only the corresponding PAA LED is lit Program starts onl...

Страница 23: ...lashing in the output area Any additional key pressure causes the start time scrolling by 1 hour 1h 2h 19h indication of remaining run time SZV 0h 1h 2h 5 3 seconds after the last actuation of the SZV key the set start time gets active and is running down Ä In addition to the LD1 display the corresponding program LED and SZV LED are lit The start time is lit in the display Start time preselection ...

Страница 24: ...except the end LED are lit 5 3 seconds after the last key actuation the set start time gets active and is running down Ä In addition to the LD1 display the corresponding program LED and the SZV key are lit The start time is indicated in the display Start time preselection gets active only when the door has been closed S1 Ein Aus LD1 S2 LD2 LD3 S3 S4 LD4 S5 LD5 LD6 S6 S7 LD7 S8 LD8 LD9 S9 S1 Ein Au...

Страница 25: ...ting 2 sec on 400mS off l Cycle end w Appliances with display w The confirmation LED for the program key of the run down cycle and the display LD1 of the ON OFF key continue to be lit w The display indicates 0 and the run time LED is lit w If there is a cycle run display depending on the variant also the end LED is lit w Appliances without display but with PAA LEDs w The confirmation LED for the p...

Страница 26: ...F key go out The program has been deleted ATTENTION In case of reduced key assemblies be sure to observe Description Page B 1 S1 Ein Aus LD1 S2 LD2 LD3 S3 S4 LD4 S5 LD5 LD6 S6 S7 LD7 S8 LD8 LD9 S9 S1 Ein Aus LD1 S2 LD2 S3 LD3 S4 LD4 S5 LD5 S6 LD6 S7 LD7 S8 LD8 S9 LD9 S10 LD10 LD11 LD12 S11 1 99 LD13 LD14 LD15 LD16 LD17 LD18 LD19 LD20 LD21 LD22 LD23 LD24 S10 LD10 LD11 LD12 S11 1 99 LD13 LD14 LD15 L...

Страница 27: ...t Ä With alternative variants of equipment see figure it is possible that only the run time to be expected or only the PAA LEDs are flashing in the output area 2 By pressing the new desired program key shortly it is possible to alter directly The already selected start time preselection is preserved after the alteration Program options already selected before however are deleted and must be select...

Страница 28: ...ctive program part If a program is altered after an already selected cycle the new cycle starts generally from the beginning This is also indicated by the run time in the display by an increase of the run time Options already selected before will be deleted S1 Ein Aus LD1 S2 LD2 LD3 S3 S4 LD4 S5 LD5 LD6 S6 S7 LD7 S8 LD8 LD9 S9 S1 Ein Aus LD1 S2 LD2 S3 LD3 S4 LD4 S5 LD5 S6 LD6 S7 LD7 S8 LD8 S9 LD9 ...

Страница 29: ...pened during the running cycle w After opening the door all indications keep to be displayed on the panel as long as the appliance remains switched on using the ON OFF key S1 w After closing the door the appliance will start automatically and the cycle run will be continued Attention w When the 1st regeneration has been reached in the program part drying the following is valid w When the door is o...

Страница 30: ...splay also the confirmation LED next to the SZV key is flashing up Ä When the start time preselection has run down the display indicates the run time to be expected of the selected washing cycle in minutes the SZV LED goes out and the run time LED is lit l Run time display RLA Ä The remaining run time is indicated via a 2 5 digit display Ä The display indicates the still remaining washing time in ...

Страница 31: ...n case of a lack of rinse aid Ä LED goes out after rinse aid has been refilled Information The rinse aid addition can be deactivated completely by the customer depending on the variant This also deactivates the LED display rinse aid see description page B 13 Deactivation of rinse aid addition When the option 3 in 1 has been selected special tablet option neither the salt LED nor the rinse aid LED ...

Страница 32: ...ivation Pulse Wash à à press keys S3 S4 change S3 see page B 17 additional washing cycle à à press keys S2 S3 change S2 see page B 18 LEDs of keys S2 S4 are flashing manufacturing service press S2 and S4 simultaneously and switch on appliance with ON OFF S1 Keep keys S2 and S4 pressed for another aprox 4 seconds until LEDs of keys S2 S4 are flashing Customer switch on appliance with ON OFF S1 à pr...

Страница 33: ... the value scrolling 4L 5L 6L 10L 1L 2L Leaving the function 4 After the last key pressure of function key S2 you can Table for hardness range values leave the special program as follows After 60 seconds all displays go out automatically except LD1 of the ON OFF key or the appliance is switched off by the ON OFF key S1 Saving the set water hardness The selected hardness range is saved directly aft...

Страница 34: ...value is indicated via the END LED see for that the table on the left side of this page Deactivation resp activation of rinse aid addition 4 5 By any further actuation of the function key S3 you can activate resp deactivate the addition alternating Leaving the function After the last key pressure of function key S2 you can leave the special program as follows After 60 seconds all displays go out a...

Страница 35: ...ND LED see for that the table on the left side of this page Deactivation resp activation of the signal sound 4 5 By any further actuation of the function key S4 you can activate resp deactivate the signal sound alternating Leaving the function After the last key pressure of function key S4 you can leave the special program as follows After 60 seconds all displays go out automatically except LD1 of...

Страница 36: ...s without 6 actuation Display 6 selection of valve display filling to level if level already existing no filling 7 actuation Display 7 selection of heating only when level detected 8 actuation Display 8 selection of circulation pump 9 actuation Display 9 selection of detergent dispenser 10 actuation Display 10 selection of drying fan Always applicable 11 actuation Display 11 selection of auto dosi...

Страница 37: ...rain pump display 6 actuation selection of the valve filling to level if leavel already existing no filling 7 actuation selection of heating only when level detected 8 actuation selection of circulation pump 9 actuation selection of detergent dispenser 10 actuation selection of drying fan Always applicable 11 actuation selection of auto dosing In order to call the totality of service functions alw...

Страница 38: ...all above mentioned LEDs resp the display have been flashing for about 30 seconds the function will be left automatically The appliance is in the prestart mode again The function can be left even earlier by switching off the appliance by the ON OFF key S1 In any case the service fault memory is deleted Always applicable In order to call the totality of service functions always first press the func...

Страница 39: ... time LED is flashing up The display indicates the presumable run time The corresponding PAA LEDs are lit From that moment the same input philosophy is valid for the manu facturing test routine as for normal washing cycles but the program LED LD4 is flashing until the end of the manufacturing test routine F cycle run and cycle end see description page B 5 Always applicable F delete cycle in advanc...

Страница 40: ... function key S3 will w Table for the indication of on off status switch the addition alternately on or off Abandoning the function After the last activation of function key S3 you can leave the special program as follows After 60 seconds automatically all indications will go dark except for the LD1 of the ON OFF key or Always applicable you switch the appliance off by means of ON OFF key S1 In or...

Страница 41: ... 4 5 Any further activation of function key S2 will w Table for the indication of on off status switch the addition alternately on or off Abandoning the function After the last activation of function key S2 you can leave the special program as follows After 60 seconds automatically all indications will go dark except for the LD1 of the ON OFF key or Always applicable you switch the appliance off b...

Страница 42: ...s not detected within 3min Programme is continued until its end without heating function NTC Sensor 7 x flashing 7 x J J NTC short circuit or break Programme is continued until its end without heating function EEPROM 8 x flashing 8 x J Communication error with ext EEPROM Check sum MCF CCF 9 x flashing 9 x J J Check sum model programming MCF or Check sum CCF not OK Only recognized after switching o...

Страница 43: ...ng element deenergized faulty wiring or no activation by electronics Thermal sensor defect Wiring faulty e g short circuit or interruption Mains filter defect Faulty electronics EMC problem i90 Check sum error model programmation Faulty electronics Blocking by dishes or cutlery basket Nozzles clogged drive nozzles at spray arm extremities Spray arm leaking welding seam Spray arm bearing blocked di...

Страница 44: ......

Страница 45: ......

Страница 46: ...programme run w All short cycles such as E L R are prolonged by about 5 to 7 minutes w All intermediate wash cycles are also shorter w Rinse aid is with at least 65 C or 68 C Drying time is reduced by about 10 to 20 minutes if possible w All Energylabel programmes AAx BAB contain at least one cleaning temperature of 55 C l Selection by using option key Sanitize To which programmes can you add this...