58
• Check the electrical and electronic system;
• Check the functionality of safety devices;
• Check the general condition of protection devices and guards.
NOTE!
It is advisable to stipulate a preventive and scheduled maintenance contract with the Customer Care Service.
Decommissioning
• All scrapping operations must occur with the machine stopped and cold and the electrical power supply disconnected;
• Work on the electrical equipment must only be carried out by a qualified electrician, with the power supply disconnected;
• To carry out these operations it is necessary to use: overalls, safety shoes and gloves;
• During decommissioning and handling of the various parts, the minimum height from the floor must be maintained.
G.18 Maintenance contacts (only for Australia)
For service and spare parts, please contact:
• Electrolux Professional – Electrolux Professional Australia Pty Ltd – 5–7 Keith Campbell Court – Scoresby, 3179 – call 03-9765-
8444
• Zanussi - Electrolux Professional Australia Pty Ltd – 5–7 Keith Campbell Court — Scoresby, 3179 – call 03-9765-8444
• Diamond - Semak Food Service Equipment - 18, 87–91 Hallam South Road, Hallam VIC 3803 – call 03-9796-4583
H
TROUBLESHOOTING
H.1
Introduction
Certain faults may occur during normal use of the appliance. In
some cases, faults can be eliminated easily and quickly by
following the indication below.
The display, if present, always shows a warning message or
alarm describing the occurring fault.
Warnings icon
Alarms signalling icon
If the fault persists, contact the Customer Care Service:
1. disconnect the appliance from the main power supply;
2. switch off the safety circuit breaker ahead of the
appliance;
3. close the gas and water tap(s), if they are present;
4. Remember to specify:
• the type of fault
• the appliance PNC (product number code)
• the Ser. No. (appliance serial number).
IMPORTANT
The appliance PNC and serial number are essential
for identifying the type of appliance and date of
manufacture.
H.2
Anomaly table
Anom-
aly
Type of
anomaly
Description
Possible causes
Actions
ACF
Warning
Air filter absent
• Filter not detected;
• Possible damage to
internal electric and
electronic components
due to air filter absence.
• Refit the filter;
• If the problem persists call Service.
ACUM
Stops
oven
Main electronic board
not identified
Communication problem
with the main electronic
board.
• Switch the oven OFF/ON;
• If the error persists, call Service.
ACUP
Stops
oven
Communication proto-
col error detected
The ACU has not been
programmed correctly. The
SD Card on the UI may be
corrupted and not able to
perform the ACU update
with the software tempora-
rily loaded on it.
• Switch the oven OFF/ON;
• If the error persists, call Service.
ACSS
Blocks
oven; fatal
error
ACS software version
(inside ACU board)
incompatible with
present UI SW
version
Wrong software upload
(example: after replacing
ACU board, the SW is not
uploaded)
ACS software version (inside ACU board)
incompatible with present UI SW version. Call
service
ACUS
Blocks
oven; fatal
error
ACU software version
(main uC) incompati-
ble with present UI
SW version
Wrong software upload
(example: after replacing
ACU board, the SW is not
uploaded)
ACU software version (main uC) incompatible
with present UI SW version.
Call Service.
!