29
Cycle displaying
• The cycle displaying can be customised as standard or
steps view. Open the lower drawer and touch the
required icon:
Saving presets
• Once the cycle is set, it is possible to save it as a preset;
Open the lower drawer and select the related icon.
Managing presets
• If you have already saved Low Temperature Cooking
presets, they show up as a list.
Touch three dots to change image, rename or delete the
presets (see the same procedure in the
CATEGORY LINK AND DELETION OF STORED PRO-
GRAMS
paragraph in F.7
chapter).
• Further actions can be done through the lower drawer.
See the available functions with presets through lower
drawer in the
paragraph in this
chapter.
At the end of the cycle the display shows the consumptions (if
available) as a recap message.
ECO DELTA COOKING
This special cycle adjusts the cavity temperature adjusts the
cavity temperature to maintain a constant difference (delta)
with the food core probe.
• Set the humidity value;
• Set the delta value for the cavity temperature;
• Then set the core probe temperature;
The display shows the set humidity value (A), for the cavity
temperature the delta value set (B) and for the probe the
current and the target values (C);
NOTE!
If creating more phases at least one of them must
be driven by probe with the cavity temperature set
as a delta from the food core temperature probe
value. Otherwise the START button is disabled and
the message “Eco delta cooking program invalid“
pops up.
• Touch
button to start the cycle.
• Once the cavity temperature is reached, load the oven and
insert the food probe in the product.
At the end of the cycle the display shows the consumptions (if
available) as a recap message.
REGENERATION
This cycle is a set of categories and cooking cycles to reheat
chilled food keeping the humidity controlled. It works as a
standard automatic cycle.
To start a regenerating cycle, proceed as follows:
1. Access the cycle;
2. Set the parameters defining the status of the food to
regenerate;
3. Touch
button to start the cycle.
CAUTION
Cold food shall not to be added to the
cavity for regeneration while the Maintain-
ing (HOLD) phase is operating.
At the end of the cycle the display shows the consumptions (if
available) as a recap message.
STATIC COMBI
65
°C
AUTOMATIC
Low temp.
Cooking
Low temp.
Cooking
01:20 h:m
PM
6:30
20°C
220°C
Standard
view
Steps
view
175
°C
∞
7
1
2
3
7
4
65
AUTOMATIC
h:m
%
°C 00:10
15
160
h:m
°C 00:20
59
%
°C
15
160
°C
65
65
°C
60
°C
°C
70
02:00 h:m
°C
60
65
65
°C
USER
AUTOMATIC
Low temp.
Cooking
01:20 h:m
PM
6:30
20°C
120°C
175
°C
Save
preset
Elux preset 1
Elux preset 2
Elux preset 3
Low temperature
cooking
User preset name 2
User preset name 1
AUTOMATIC
USER
Elux preset 1
Elux preset 2
Elux preset 3
Low temperature
cooking
User preset name 2
User preset name 1
AUTOMATIC
USER
Abc
T
7
20°C
50%
15
°C
°C
51
70°C
02:35 h:m
30
%
A
B
C
USER
AUTOMATIC
Custom
Probe
Plate
AUTOMATIC
USER
Timer
Cooking control
Probe
Timer
Load
Standard
Full
Humidity content
Dry
Medium
Moist
23
°C
50°C
Custom