![Electrolux Professional A7FTEDCSI0 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/electrolux-professional/a7ftedcsi0/a7ftedcsi0_service-manual_2385587017.webp)
17
FRY TOP 700/900 EL/GAS
2
INSTALLATION
AND
COMMISSIONING
2.1 INSTALLATION
The following chapters are intended only for authorized technicians / engineers
UNPACKING
AND
POSITIONING
THE
EQUIPMENT
2.1.1.1
ROOM
REQUIREMENTS
To guarantee continuous operation, the room temperature range must be between 5°C and 40°C.
Outdoor functioning is strictly allowed only if the machine can be protected against any conditions being out of
the above temperature range and against any atmospheric agents.
On a hot cupboard base take precaution to install a baffle for preventing hot air to reach the oven fresh air
intake; this could create malfunctioning.
High room humidity may cause water to condensate on electric components hence causing short circuit.
LIMITATIONS
LIST
OF
POSSIBLE
INSTALLATION
SOLUTIONS
Hereinafter, the instructions for the main installation possibilities. The different accessories have a dedicated
I.M; please refer also to these documents provided with the accessories or available on PRIDE.
2.1.3.1 ON
BASE
All top appliances can be fixed onto
neutral bases
.
WARNING / CAUTION !
Before any operation on the machine read Chapter
. We recomand for any phase involving the re-
moval of the packaging to use cut-resistant gloves
OUT, foot
IN, M6
bolt to fix
top
IMPORTANT: We suggest to use a M6
25mm bolt to fix the top to the base unit, it
makes the job much easier than using the
foot (inside the base there are some inter-
ference, job can be done bit an M6 bolt is
much faster with a spanner than with foot.
Top
Neutral
Base
Содержание A7FTEDCSI0
Страница 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Страница 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Страница 62: ...62 FRY TOP 700 900 EL GAS 6 3 2 1 GAS VALVE 6 3 2 1 1 700 The temper ature probe of the 700 gas valve ...
Страница 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Страница 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Страница 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...
Страница 71: ...71 FRY TOP 700 900 EL GAS 6 3 3 4 SAFETY THERMOSTAT 700 900 ...