![Electrolux Professional A7FTEDCSI0 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/electrolux-professional/a7ftedcsi0/a7ftedcsi0_service-manual_2385587026.webp)
26
FRY TOP 700/900 EL/GAS
2.3.1.1 700
GAS
APPLIANCES
The 700 appliances have a different valve than the 900. The Igniter of the burner for the 700 appliances is
external to the valve (piezo push button).
NOMINAL SUPPLY PRESSURE CHECK:
The nominal valve inlet pressure check must be measured while
the appliance operates, using a manometer (min 0,1 mbar).
Remove the pressure access point screw “ 6 ”; connect a monometer “ O “; compare the value read on the
manometer to the value to the data given in the tech specs tables (Refer to §
TECHNICAL CHARACTERIS-
TICS
).
Fit back the access point screw “ 6 ”after finishing the checking.
CAUTION!
If the manometer gives a reading outside the range value indicated in the tech specs (high pressure
or low pressure), do not terminate the commissioning of the appliance and inform the customer/gas
company.
GAS VALVE OUTLET PRESSURE CHECK
:
Remove the pressure access screw “ 7 “
Connect the manometer “ O “ to the access “7” the
outlet pressure to the burner can be measured.
NO ADJUSTMENTS ARE REQUIRED.
Supply the appliance with the correct pressure as
indicated in tech specs tables (Refer to §
TECH-
NICAL CHARACTERISTICS
) according also to
the type of gas. Turn on the frytop to check dy-
namic pressure on both access “6” and “ 7 “.
PILOT BURNER ADJUSTMENT (gas flow)
:
The adjustment of the pilot flame is obtained and
set in the factory, however, in case of need: turn
the screw
“
5
“ clockwise to reduce flow, counter-
clockwise to increase.
Содержание A7FTEDCSI0
Страница 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Страница 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Страница 62: ...62 FRY TOP 700 900 EL GAS 6 3 2 1 GAS VALVE 6 3 2 1 1 700 The temper ature probe of the 700 gas valve ...
Страница 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Страница 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Страница 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...
Страница 71: ...71 FRY TOP 700 900 EL GAS 6 3 3 4 SAFETY THERMOSTAT 700 900 ...