23
FRY TOP 700/900 EL/GAS
HOW
TO
RECOGNIZE
PHASE
AND
NEUTRAL
Normally this job is up to a skilled electric engineer that carries out his work before ours, however; in case of
need, some basic tips on how to check the supply wires before our main terminal board.
GAS appliances are NOT power supplied.
ELECTRIC appliances are three phase supplied
(L1+L2+L3)
Put your meter in AC Volts setting. Connect supply to the main terminal board
MA
but do not turn on the ap-
pliance. Connect the meter test leads to the terminal board contacts; the readings should be:
L1 / L2 / L3 + N* (Phase and Neutral) =
230 Volts
(+/- 6% based on European standards)
L1 / L2 / L3 + (Phase and Earth) =
230 Volts
L1 and/or L2 + L3 (Phase and Phase) =
400 Volts
N + (Neutral and Earth) =
0 Volts
(or approx. zero V)
The combination and results obtained will permit you
to find all wires: PHASE, NEUTRAL and EARTH.
WARNING!
Take GREAT CARE when testing anything with live current and always use you personal protective
equipment; if you are unsure what you are doing and how to use your equipment safely then
DON'T
DO IT
Содержание A7FTEDCSI0
Страница 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Страница 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Страница 62: ...62 FRY TOP 700 900 EL GAS 6 3 2 1 GAS VALVE 6 3 2 1 1 700 The temper ature probe of the 700 gas valve ...
Страница 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Страница 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Страница 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...
Страница 71: ...71 FRY TOP 700 900 EL GAS 6 3 3 4 SAFETY THERMOSTAT 700 900 ...