![Electrolux Professional A7FTEDCSI0 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/electrolux-professional/a7ftedcsi0/a7ftedcsi0_service-manual_2385587033.webp)
33
FRY TOP 700/900 EL/GAS
2.5.1.2 900
GAS
SUPPLIED
The 900 appliances have a different valve than the 700 and the ignition procedure is different.
To turn on (start) the appliance:
The gas control knob is located on the control panel and has the following positions:
Ignition (turning ON the appliance)
1.
Press and turn knob “M “ lightly and turn it counterclockwise to release it from the
position
2. Press fully the
“M “ knob and turn it into pilot ignition
position; a click will indicate that a spark has been
generated. Repeat the sparking process (keeping pressed the knob "M" ) a few times until the pilot has been
lit.
3. Keep knob “M“ pressed for about 20 seconds in such manner the thermocouple can heat up and give
consents to the valve to deliver gas.
4. When knob “M“ is released in
position , make sure that the pilot flame remains alight; otherwise, repeat
the operation.
5. Once the pilot is lit, start the appliance by rotating the
“M” valve knob to the position “Burner ignition”.
6. Regulate the desired temperature of top
by rotating the temperature knob “N “.
Switching off burner / turning off the appliance
1. To turn off the burner p
artially press knob “M“ and turn it from to
position to keep the pilot flame lit
for subsequent cooking;
2. to turn off pilot p
artially press knob “M“ and turn it from the
position into the
to switch off the appli-
ance.
NOTE!
The valve features a thermal re-light locking device enabled until the thermocouple is hot. Such
device, called interlock, keeps engaged for about 40 seconds in case of accidental pilot flame shut
off, hence allowing accumulated gas to flow out through the chimney prior to light any spark again.
Forcing the interlock leads to a valve damage which is not covered by the original manufacturer
warranty. .
Содержание A7FTEDCSI0
Страница 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Страница 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Страница 62: ...62 FRY TOP 700 900 EL GAS 6 3 2 1 GAS VALVE 6 3 2 1 1 700 The temper ature probe of the 700 gas valve ...
Страница 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Страница 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Страница 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...
Страница 71: ...71 FRY TOP 700 900 EL GAS 6 3 3 4 SAFETY THERMOSTAT 700 900 ...