46
FRY TOP 700/900 EL/GAS
4.2.1.3 PILOT
&
THERMOCOUPLE
INTERRUPTED
700
&
900
700 and 900 app
liances use different TC’s but the functioning is the same.
The TC, if correctly aligned with the pilot flame, will generate approx 8/10 MilliVolt, that can keep the magnetic
coil of the valve opened (coil of valve requires approx 1,5MilliVolt to keep engaged)
The TC must be inserted completley into the pilot bracket and then fixted in place by tightening the nut.
Содержание A7FTEDCSI0
Страница 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Страница 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Страница 62: ...62 FRY TOP 700 900 EL GAS 6 3 2 1 GAS VALVE 6 3 2 1 1 700 The temper ature probe of the 700 gas valve ...
Страница 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Страница 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Страница 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...
Страница 71: ...71 FRY TOP 700 900 EL GAS 6 3 3 4 SAFETY THERMOSTAT 700 900 ...