![Electrolux Professional A7FTEDCSI0 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/electrolux-professional/a7ftedcsi0/a7ftedcsi0_service-manual_2385587042.webp)
42
FRY TOP 700/900 EL/GAS
Valve description:
Manual thermostatic gas valve (EUROSIT), the pipes can be loosened with a wrench while the thermostat
capillary need to be loosened from its housing.
Please note that the igniter is external to the valve, on the control panel you will find a piezo igniter (external
component).
1 Valve capillary and thermostat probe
2 Maximum gas flow adjustment screw
3 Minimum gas flow adjustment screw
4 Knob
5 Pilot flow adjustment screw
6 nominal inlet pressure access
7 outlet pressure (from valve to burner) access
8 Pilot burner connection outlet
9 Thermocouple connection / magnetic coil (flame failure device requires 1,5MilliVolt to engage)
10/12 Main gas inlets
11/13 Main gas outlets
14 Minimum screw / adjustment port
15 Maximum screw / adjustment port
Содержание A7FTEDCSI0
Страница 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Страница 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Страница 62: ...62 FRY TOP 700 900 EL GAS 6 3 2 1 GAS VALVE 6 3 2 1 1 700 The temper ature probe of the 700 gas valve ...
Страница 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Страница 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Страница 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...
Страница 71: ...71 FRY TOP 700 900 EL GAS 6 3 3 4 SAFETY THERMOSTAT 700 900 ...