ELECTRO FREEZE Shake Model CS705
184592
27
1. In areas where state and local
health codes allow, product may remain in
the freezer overnight, leave the Selector
Switch in the “AUTO” position and the
syrup switch to the “OFF” position.
Note: The plunger rod and cover must be
in place for the unit to operate.
2. Clean all soiled surfaces with a
warm dish detergent solution.
3. Turn the mix feed regulator to the
“CLOSED” position as shown in figure 9-2.
Figure 9-2
Mix Feed Tube Positions
9.1.2
Operation
Look through top hole
in tube — you should
see clear through.
Look through top
hole in tube — you
should see the inner
white plastic tube
(regulator) blocking
the opening.
Pin is in line with hole.
Pin is not in line with hole.
DAY
NIGHT
4. Check mix level in hopper to ensure
that there is enough mix to keep the indica-
tor light off, add mix if necessary.
Do not
dispense product when the mix feed
regulator is in the “CLOSED” position.
5. Before serving from the machine
use the wash bottle and spray the plunger
and mix chamber opening with sanitizing
solution and “OPEN” the mix feed regulator
and fill the hopper with mix (figure 9-2)
.
Содержание COMPACT Series
Страница 2: ...This page is intentionally blank ...
Страница 10: ...This page is intentionally blank ...
Страница 15: ...ELECTRO FREEZE Shake Model CS705 184592 5 3 5 Dimensions Figure 3 2 Electro Freeze Model CS705 Dimensions ...
Страница 16: ...ELECTRO FREEZE Shake Model CS705 184592 6 4 Part Names and Functions Figure 4 1 Head Assembly 19 20 ...
Страница 24: ...ELECTRO FREEZE Shake Model CS705 184592 14 Figure 6 2 Dispense Head Assembly 6 2 DisassemblyInstructions ...
Страница 30: ...ELECTRO FREEZE Shake Model CS705 184592 20 Figure 7 4 Head Assembly 7 Assembly continued ...