background image

 

 

Part Description 

EASASD-10 

EASASD-11 

EASASD-12 

EASASD-18 

On/Off Switch 

R1-0205 

R1-0205 

R1-0205 

R1-0205 

Safety Interlock Switch 

R1-0202 

R1-0202 

R1-0202 

R1-0202 

Performance Indicator Light (Green LED) 

R1-0123 

R1-0123 

R1-0123 

R1-0123 

Air Proving Switch 

D1-0217 

D1-0217 

D1-0217 

D1-0217 

24 Volt Transformer 

D1-053D 

D1-053D 

D1-053D 

D1-053D 

Power Board 

D1-055D 

D1-055D 

D2-055D 

D2-055D 

Fibreboard (with 4 Copper Contacts) 

D0-0521 

D1-0521 

D2-0521 

D8-0521 

Copper Contact 

R1-9925 

R1-9925 

R1-9925 

R1-9925 

Cord Assembly (Optional) 

R1-062D 

R1-062D 

R1-062D 

R1-062D 

10 

Cover for Power Box 

D0-0509 

D1-0509 

D0-0509 

D1-0509 

11 

Power Box Complete (No Cover) 

Depends on options with power box 

12 

Carbon Filters (Set of 3) 

1156-3 

1156-3 

1856-3 

1856-3 

13 

Prefilter 

R0-0855 

R1-0855 

R2-0855 

R8-0855 

14 

Cell Guide (Plastic) 

R1-0603 

R1-0603 

R1-0603 

R1-0603 

15 

Collecting Cell 

D0-0400 

D1-0400 

D2-0400 

D8-0400 

16 

Cell Handle 

R1-0484 

R1-0484 

R1-0484 

R1-0484 

17 

Door (with Plastic Clip & Handle) 

D0-0632 

D1-0632 

D2-0632 

D2-0632 

18 

Door Handle (Plastic) 

R1-0634 

R1-0634 

R1-0634 

R1-0634 

19 

Ionizing Wire 

D1-0443 

D1-0443 

D2-0443 

D2-0443 

20 

Male & Female Door Clip Set 

R1-0636 

R1-0636 

R1-0636 

R1-0636 

21 

Dax Detergent 

9900 

9900 

9900 

9900 

Parts List 

Use the diagram on the preceding page to identify the part which is required. To order 
parts call the number listed at the bottom of the page or call your local contractor. 

11 

ELECTRO-AIR CANADA 

351 North Rivermede Road, Concord, Ontario, Canada  L4K 3N2 

Tel:  (416) 213-5636                Fax:  (416) 213-5593 

Toll Free  1-800-267-8305 

Содержание EASASD-10ASC

Страница 1: ...rease mold fungi bacteria viruses and more down to 0 01 micron Dual Voltage Aluminum Collecting Cells are durable and easy to maintain Cell Guide ensures proper placement of collecting cells Activated...

Страница 2: ...of electrostatic precipitation Millions of airborne pollutants are carried through the return air ducts of the heating cooling system and treated through four stages of filtration The prefilters 2 re...

Страница 3: ...the Air Cleaner will vary with CFM and whether the carbon filters have been installed in the unit Location The Air Cleaner must only be installed in the return air duct as close to the fan compartment...

Страница 4: ...ifier must be installed as far from the Air Cleaner as possible 2 Collecting cells must be washed frequently to prevent a mineral deposit build up Installation Location With Air Conditioner Whenever p...

Страница 5: ...ent direction than the left to right set up The handle should face the door Close access door Wiring Wiring should only be performed by qualified personnel only All wiring must comply with all applica...

Страница 6: ...a non chlorine non corrosive non abrasive liquid household detergent Allow detergent to run down both sides of plates and ionizing wires Let stand for 5 minutes or fill up laundry tub with water and...

Страница 7: ...igh Voltage At Power Board A high voltage meter capable of measuring up to 10 000 VDC is required to test the voltage 1 The Air Cleaner should be ON with the cells installed the door closed and the sy...

Страница 8: ...e performance light will come on The light on the power switch will be lit even when the APS is open If the power board fails to come on with the fan on check that the sensor is properly set down to t...

Страница 9: ...ner 8 Remove the high voltage meter 9 Replace the power box cover 10 Turn ON the Air Cleaner Setting Approximate Voltage Without High Voltage Meter A high voltage meter should be used to set the high...

Страница 10: ...olding the power box to the cabinet 5 Slide the power box forward then up to remove it from the cabinet 6 If you are removing the power box for any length of time tape a cover over the top opening to...

Страница 11: ...options with power box 12 Carbon Filters Set of 3 1156 3 1156 3 1856 3 1856 3 13 Prefilter R0 0855 R1 0855 R2 0855 R8 0855 14 Cell Guide Plastic R1 0603 R1 0603 R1 0603 R1 0603 15 Collecting Cell D0 0...

Страница 12: ...making good connection on cell With needle nose pliers gently pull contacts down or replace contacts Cells arcing excessively power light and per formance indicator light ON or flashing Cells wet fro...

Страница 13: ...basis for the Air Cleaner to function at its peak of efficiency The frequency of cleaning will vary from one house to another On average the cells should be cleaned every 3 months Use the chart below...

Страница 14: ...NOTES 14...

Страница 15: ...pairing removing installing shipping servicing or handling of either defective parts or replacement parts Such costs may be covered by a separate warranty provided by the dealer LIMITATIONS OF WARRANT...

Страница 16: ...of the furnace or air handler ensure that there is 115 Volt output from these terminals when the unit is run manually and is running on low speed Some manufacturers do not supply full output voltage...

Отзывы: