The water heaters models electric circuit schema are shown on Fig. 1  and  Fig.  2, the number
indications are provided in Table 3.

2.1 Connecting to UPS

The manufacturer has installed the tank so that it will work without an UPS device. In case of
necessity to supply power with an UPS device, it is necessary to use the column terminal labeled 2
in Fig. 1 and Fig. 2 in order to remove the wires (bridges) connecting terminals   L to UPS with L
from UPS and N to UPS with N from UPS, indicated by a dotted line. To the terminals thus empties
connect the UPS device. The UPS power cable is connected to the terminals L to UPS (phase) and
N to UPS (zero). The UPS output is connected to the terminals L from UPS (phase) and N from
UPS (zero).

IMPORTANT!

 It is obligatory to connect correctly the output cable of the UPS to the right terminal in

the unit, i.e. compliance with phase and zero!
When removing the power supply from the UPS device the wires must be reconnected to the
column bridge terminal 2, respectively L to UPS to L from UPS and N to UPS to N from UPS.

ATTENTION!

 In case of improper connection of UPS or improper recovery of the bridging wires, the

electronic unit will not work and it is very possible to damage it and increase the risk of electric
shock!
It is necessary to secure the power cord to the power circuit of the water heater and the power cord
from the UPS to the electronic unit against displacement by using the cable clamp located next to
the hole for the cable in the plastic cap.

Table 3 - Indications and terminals of the electronic unit components* in Figures 1-2

Functions

Installation / Purpose

1

Unit power supply

2

UPS terminal

3

Thermal   sensor   NTC   10K,
2m, PVC

It is installed in the middle part of the water heater above the lower heat
exchanger (coil-pipe). Measures the temperature - t5

4

Thermal   sensor   NTC   10K,
0.5m, PVC

It is installed in the lower part of the water heater next to the electric
heater, Measures the temperature - t1

5

Circulation pump 1

Controls circulation pump 1

6

Circulation pump 2

Controls circulation pump 2

7

Thermal   sensor   NTC   10K,
2m, PVC

It is installed in the upper part of the water heater above the top heat
exchanger (coil-pipe). Measures the temperature - t2

8

Thermal   sensor   pt1000,
0.5m, Teflon

It is installed in the solar collector. Measures the temperature - t3

9

Thermal   sensor   NTC   10K,
2m, silicone

It is installed in a boiler, fireplace or other. Measures the temperature -
t4.

10 Magnesium anode

Not available in water tanks made of chrome-nickel steel.

11 Heaters

5

Содержание NHC-H52M-1S

Страница 1: ...ation and operation instruction attached to your water heater unit All of the general instruction requirements concerning the water heater installation and connection to the water supply and electrici...

Страница 2: ...e listed in Table 2 Table 1 Models and features of the electronic units NHC H52M 1S NHC H52M 2 Thermostat control of the utility storage water electric heater heaters Control of the utility storage wa...

Страница 3: ...eater Each interval can be set in any day of the week to switch on and to what temperature water can be heated Control of the solar collector circulation pump power depending on the temperature differ...

Страница 4: ...tional protective conductor that never should be interrupted and or connected on the layout from the electric panel to the tank Otherwise the appliance shall not be correctly earthed and it shall redu...

Страница 5: ...unit will not work and it is very possible to damage it and increase the risk of electric shock It is necessary to secure the power cord to the power circuit of the water heater and the power cord fr...

Страница 6: ...wires in water heaters designed for wall mounting with one heat exchanger Fig 1 and with two heat exchangers Fig 2 The power cord phase conductor connects to the thermal cut out terminal labeled A1 or...

Страница 7: ...Fig 2 Single phase connection of water heaters with two heat exchangers NHC H52M 2 3 DISPLAYS SETTINGS MENUS 3 1 Main display graphics and indications Fig 3 7...

Страница 8: ...do not make any changes for a longer period between 20 seconds and 5 minutes depending on the settings menu you will automatically exit the selected menu without saving any changes made The only excep...

Страница 9: ...protection against overheating of the solar collector by automatically switching to Holiday mode to discharge the stored energy 3 5 2 On All authorized heat sources shall be switched on see menu Heati...

Страница 10: ...line but in column Off on the same line When this pump works the circulating pump on the image of the boiler on the display will rotate To protect the water tank from overheating the circulation pump...

Страница 11: ...h off There is one more operation mode for the boiler pump set from the menu Heating Installation row Boiler Pump Mode CH Priority When this mode is activated in the menu Pumps control shall be used t...

Страница 12: ...erature and it will switch on if the temperature of the lower thermo sensor t1 drops by 5 degrees less than the temperature set in Temp The timer allows exclusion of certain days of the week during wh...

Страница 13: ...temperature that can be used for any household needs but at the same time if there is a strong sun it can take as well its heat 3 10 Pumps control Temperature settings for switching on and off the pum...

Страница 14: ...accumulated heat in the water tank when you activate Holiday mode the temperature will be reduced to the value set in this field Use boiler pump NHC H52M 2 When this field is checked the discharge of...

Страница 15: ...rature settings ATTENTION When for long periods you do not use hot water and the sun is strong enough do not disconnect the water heater from the apartment electricity panel This can damage the standi...

Страница 16: ...y collected in the water heater during the day Holiday mode Solar anti frost Switched on mode for protecting the solar collector against freezing Freezing protection of the boiler Switched on mode for...

Страница 17: ...d date to when the thermostat is working before you interrupted power supply Power supply on Time and date when the power supply is restored These messages will be registered only if the system clock...

Страница 18: ...creen is the date concerning the information displayed while at the bottom is provided a summary for the day 4 5 Information By pressing the button Enter after the state Statistics by the hours shall...

Страница 19: ...thermostat shall continuously monitor the temperature as the water in the water tank and the solar collector If necessary the protection mode shall be switched on for Anti freezing protection of the...

Страница 20: ...late a new heat in order to discharge the solar collector The pump will operate until the temperature in the tank falls below the temperature set in Solar protection line Tank min temp This mode is in...

Отзывы: