(Freezing
protection)
electric heater it warms the water in the tank to avoid freezing while the solar pump
discharges the heat from the water heater, in order to protect the solar collector as
well.
Solar protection
Prevents eventual overheating of the solar collector. If the solar collector thermo-
sensor (t3) is not operating (not working), the solar pump shall be turned on constantly
to avoid any possible overheating.
Holiday
The water heater is in manually activated
Holiday mode
, which aims unloading the
accumulated heat during the night so that the next day when reheated by the sun
overheating of the solar collector is prevented.
Standby
The electric heater is switched off.
4.2 Information field (Fig. 3)
Basically in this field is displayed the date starting with the day of the week in the following format:
DD/MM/YYYY. Upon registration of a failure of the self-test system, in the bottom line field shall
alternate the date and the (error) message while a clear sound shall be audible as well.
The (error)
messages are listed in Table 6:
Table 6 - Information field messages
Message
Description
No information!
At the moment there is no information concerning new issues or errors
Switch on Holiday
mode
Switched on mode for discharge of the heating energy collected in the water heater
during the day. (Holiday mode).
Solar anti-frost
Switched on mode for protecting the solar collector against freezing.
Freezing protection
of the boiler
Switched on mode for protecting the water heater from freezing.
Error reading image
Error during downloading an image from the schematic diagram of the heating
system to the main screen.
Disconnected S1
Failure of the bottom thermal sensor of the water heater (t1). It may be either
interrupted/disconnected or switched off.
S1
in short-circuit
Failure of the bottom thermal sensor of the water heater (t1). It is in short-circuit.
Disconnected S2
Failure of the bottom thermal sensor of the water heater (t2). It may be either
interrupted/disconnected or switched off.
S2
in short-circuit
Failure of the top thermal sensor of the water heater (t2). It is in short-circuit.
Disconnected S3
Failure of the solar collector thermal sensor (t3). It may be either
interrupted/disconnected or switched off.
Only the modes with electric and boiler
heating shall be operative.
In this situation the solar installation circulation
pump will work continuously to protect the solar collector from overheating!
S3
in short-circuit
Failure of the solar collector thermal sensor (t3). It is in short-circuit. Only the modes
with electric and boiler heating shall be operative.
In this situation the solar
installation circulation pump will work continuously to protect the solar
collector from overheating!
16