Disconnected S5
Failure of the middle thermal sensor of the water heater (t5). It may be either
interrupted/disconnected or switched off.
S5
in short-circuit
Failure of the middle thermal sensor of the water heater (t5). It is in short-circuit.
Frozen boiler
When switching on the power the water in the water heater has negative
temperature and may be frozen. You need to check the integrity of the water
container and only then switch on the power again.
Solar unprotected
The solar installation is switched off from the menu „
Heating Installation
” and if it is
installed it may be damaged either by overheating or by freezing.
Off all heaters!
All heating sources are switched off from the menu „
Heating Installation
”. If the
solar installation is installed it may be damaged either by overheating or by freezing.
The same is true for switching off the water heater freezing protection mode.
Solar overheating
Solar collector overheating shall be registered when the t3 temperature exceeds the
temperature in the field
„Solar overheating“
from the menu
„Solar protection“
Error reading image
The test for reading the images displayed on the screen is not passed.
Anti-Legionella
Activated mode for destroying the Legionella bacteria by heating the water with
electric heater to 70 degrees.
Power supply off *
Latest time and date to when the thermostat is working before you interrupted power
supply.
Power supply on*
Time and date when the power supply is restored.
* These messages will be registered only if the system clock has been set.
4.3 Delete alarms (triggered by errors)
When one of any registered issues (errors) causing activation of the alarm is fine, the message that
was about it, disappears from the information field.
If all error messages disappear stops and alarm. Exceptions are issues as
„Solar overheating“
and
„Boiler overheating“
, to erase error messages and signals for alarm should be deleted from
the diagnostics thermostat display. To do this you must first press the key Enter twice from the main
display to enter the display
„Diagnostics“
. Then again press and hold the Enter key for over 3
seconds to erase all messages concerning issues.
If any of the heating sources is not activated from the
„Heating Installation“
menu it shall be
displayed dimmed and the corresponding field for the temperature measured shall not be displayed.
If the electric heater is not activated, it will not be visible.
If the clock is not set, it will be displayed with hyphens: --:--. The thermostat has a battery that
supports the timing of short-term power failure. The maximum time for time support is 48 hours,
then the clock shall turn off and shall need your re-verification.
If in the middle part of the display there is not the image of Fig. 4 we recommend to reset the
thermostat by turning off power to the boiler, and then turn it on again!