EN
14
to 3 °C, thus preventing it from freezing.
IMPORTANT! This function is effective only if applied to the water heater power supply and there is an
indication on the display.
Electronic block performances in cases of cutting and recovering power supply
In case of short-term suspension of power supply to the water heater, the built-in battery keeps the clock operating
for more than 18 hours. After this period, the clock is reset and must be set again. Resetting the clock switches off
the modes Delayed start and Heating with timer. When the power failure was short and the clock has saved your
settings, when power supply is restored, the unit switches on in a mode in which it was before its accidental
switching off.
Additional information on the water heater operation
At the display left bottom, in the field for measurement and input parameters and, in some cases on the entire
display, can be seen various data. They are displayed one after another by pressing the button
Г
. The order of data
display is as follows:
-
The temperature set for hot water;
-
Total consumed daylight electricity from the first unit switching on and clock setting. This
indication can be reset by pressing and holding the button for more than 5 seconds;
-
Total consumed nighttime electricity from the first unit switching on and clock setting. This
indication can be reset by pressing and holding the button for more than 5 seconds;
-
Diagram of electricity consumption in percentages by hours of the day;
-
Diagram of electricity consumption in percentages by hours of the previous day;
-
Diagram of electricity consumption in percentages by hours of the previous seven days;
-
Start time of daylight rate;
-
Start time of nighttime rate;
-
Current date;
-
Start time of first scheduled period;
-
End time of first scheduled period;
-
Start time of second scheduled period;
-
End time of second scheduled period.
Warning messages and additional protections
At the top of the display may can be displayed the following messages:
џ
Anode Low - The anode is worn or its corrosion protection chain is severed. A qualified person by an
authorized manufacturer service must review the corrosion protection. Using the unit with damaged