3.

Programming Instructions

The  Transponder  TRS06  employs  AUTO  EXITING  software  for  security 
reasons. In any of the programming modes, the controller will automatically 
revert back to standard operating mode if the user takes no action within 30 
seconds.

There  are  three  different  operating  modes,  as  indicated  by  the  display  dot 
position:

It  is  recommended  that  the  user  reads  the  user  actions  and  controller 
responses carefully before attempting to program the controller.

The column user action indicates the steps the user must take to accomplish a 
certain programming function.

The column controller response indicates the response that the controller will 
give to a user action.

Standard Operating Mode

Position 1

User Tag Learning Mode

Position 2

Deleting Mode

Position 3

Master tag learn mode

Position 4

 

 

 

 

6

Содержание TRS06-01

Страница 1: ...TRS 06 TRANSPONDER READER AND CONTROL UNIT Door Access Control System Mounting Manual and Operating Manual ...

Страница 2: ...uildings and also to garages or multi storey car parks up to 1000 users Two versions of the Transponder System are available TRS06 01 has a standard reader head whereas TRS06 02 provides a vandal proof reader head To gain access a Transponder Card registered at the control unit or a TransponderTag can be held to or passed by the reader head A high standard of security is offered by the 64 bit codi...

Страница 3: ... Mount the reader head Make sure that the cable is not pinched off 2 Only regarding the standard reader head place the reader head sticker onto the reader head and align the reader head sticker LED hole with the LED of the reader head 3 Connect the reader head with the control unit according to the wiring details page 5 Standard Reader Head Vandal Proof Reader Head LED Foil blue buzzer BUZ red pow...

Страница 4: ...d Buzzer blue from reader head Loop yellow from reader head Loop green from reader head Aux 0V bridge between RTE or Fire RTE request to exit input Fire fire alarm input normally open Relay N O normally open relay contact Common common relay contact N C normally closed relay contact Failure to follow the wiring instructions may result in permanent damage to the controller Wiring Reader Heads In ca...

Страница 5: ...lose the circuit to open all doors immediately Please note the fire alarm input is non latching and fail safe locks should be used with this function N C OV COMMON LOOP SELECT LOOP AC 12 V AC DC 1 A Reader Head Key switch Red N O LOOP AC FIRE RTE BUZZER OV 5V Black Blue Yellow Green Input fire alarm Closing Contact Exit request Magnetic Lock 5 ...

Страница 6: ...ated by the display dot position It is recommended that the user reads the user actions and controller responses carefully before attempting to program the controller The column user action indicates the steps the user must take to accomplish a certain programming function The column controller response indicates the response that the controller will give to a user action Standard Operating Mode P...

Страница 7: ... the last card read while pressing this button in standard mode 2 While still holding button S1 press button S2 the bottom button The controller will respond with three beeps immediately After releasing buttons S1 and S2 the controller display will light up displaying This indicates that the controller is in master tag learning mode and that the first tag to be presented to the reader will be the ...

Страница 8: ...learning mode 2 Remove the master tag and present the new user tag s to be learned one at a time to the reader Wait for response of the controller 1 second after presenting a new user tag the controller will respond with a single beep This indicates that the controller has learned the new user tag Note Should the controller respond with 3 beeps instead it is indicating that the 1000 user limit has...

Страница 9: ...rgets to exit user tag learning mode the unit will automatically exit this mode after 30 seconds Note Deleting user tags can only be done if the number is known After completing user tag programming present each tag to the reader again see chapter Read Last User Tag Note down the number displayed e g together with the name of the owner New user tags can be programmed any time New user tags will be...

Страница 10: ...r responds with an additional 3 beeps indicating that it has entered user tag learn mode 2 Press button S2 The controller responds with 3 beeps and after S2 is released is displayed This indicates that the controller has antered user tag voiding mode 3 Press button S2 to scroll to the user tag number that has to be voided from the system Note By holding button S2 in the scrolling speeed will incre...

Страница 11: ...om the system press S1 button The controller responds with a single beep and the display changes to The user tag has been deleted 5 To exit user tag deleting mode do not make any input into the controller for 30 seconds Unit responds with 3 beeps and enteres the standard mode 11 ...

Страница 12: ...he relay output time the door alarm settings will need to be reset at the same time 1 Press S2 and release Unit responds with 3 beeps and shows t 1 second 2 Continue pressing S2 to increment the timer until the required time setting is achieve The display shows t 2 seconds up to t 9 seconds or t this is a special setting for a 150ms Pulse Output 3 Do not make any input into the unit for 30 seconds...

Страница 13: ... Function User Action Controller Response Looking for the last tag read 1 In standard mode press and hold S2 The number of the last tag read will be displayed 2 Release button S2 3 5 Last Tag Read Instructions 13 ...

Страница 14: ...ype Reader heads 1 or 2 Reader head cable length 2 m standard max 5 m unshielded max 15 m shielded Cable 5 core Degree of protection reader head IP54 controller IP00 Dimensions L x W x D reader head 75 mm x 39 mm x 15 mm controller 104 mm x 94 mm x 25 mm Weight reader head 60 g controller 70 g Operating temperature 10 C to 60 C Indications visual bi color LED acoustic Buzzer Software Programming w...