2.2 Installing the Controller
1. Remove the cover. Insert the cables through the bottom of the cover from the
backside. Secure the control unit in the preferred location using the screws
and mollies.
2. Connect the reader heads (also see below) as well as the power supply and
any auxiliary devices to the control unit according to the wiring details (page
5) and fasten the cover with screws.
2.3
Wiring Details Control Unit
Power
AC / DC
12 V AC / DC
AC / DC
12 V AC / DC
Reader Head
+ 5V
red
from reader head
- 0V
black
from reader head
Buzzer
blue
from reader head
Loop +
yellow
from reader head
Loop -
green
from reader head
Aux
- 0V
bridge between RTE or Fire
RTE
request to exit input
Fire
fire alarm input (normally open)
Relay
N/O
normally open relay contact
Common
common relay contact
N/C
normally closed relay contact
Failure to follow the wiring instructions may result in permanent
damage to the controller!
Wiring Reader Heads
In case two reader heads are to be installed the Jumper LOOP SELECT must be
CLOSED and the second reader head must be wired in parallel to the controller.
Please note, that this is a
single door system
and there is only one output relay.
The two heads will therefore be fitted to the ENTRY and EXIT points on a
single
door.
4