Programming
Function
User Action
Controller Response
Adjust the door
lock mecha-
nism
Relay
Output Time
.
This function is
used to set the
time, for which
the relay will
provide an
output to the
door latch, in
the event of a
card/tag being
introduced or
fire exit (RTE)
push button.
The default
setting is
t1
(1 second).
Note: When
resetting the
relay output
time the door
alarm settings
will need to be
reset at the
same time.
1. Press S2 and
release.
Unit responds with 3 beeps
and shows:
t = 1 second
2. Continue pressing
S2 to increment the
timer until the
required time setting
is achieve.
The display shows:
t = 2 seconds, up to
t = 9 seconds
or t = - (this is a special
setting for a 150ms Pulse
Output)
3. Do not make any
input into the unit for
30 seconds to exit
this mode or press
S1.
Unit responds with 3 beeps
and enteres standard mode..
3.4
Relay Output Time Programming Instruction
12