207-SM Control Panel Instruction 12VDC and 24VDC For Swing Gates 
 

General safety rules 
WARNING: 

Unskilled  personnel  should  never  be  allowed  to  assemble,  repair  or  adjust  the  devices  and  all  necessary 

precautions  must  be  taken  to  prevent  accidents:  power  supply  disconnected  (including  backup  batteries  if  present).This 
product is not suitable for installation in explosive atmospheres.

 

 
 
Keep  this  handbook  carefully,  store  it  attached  to  the  technical  installation  leaflet  in  a  safe  place  where  it  is 
available to anyone who may need it and make sure that all involved personnel are aware of this. 

 

 

 

 

 

Type of product 
 

The 207 control panel has been designed to control 1 or 2 operators 12VDC and a 24VDC version for swing gates. It has an 
on-board integrated radio receiver. It is also possible to set the slowing down and anti-crushing features that grant an easy 
and  safe  installation,  free  from  interference  and  protected  against  atmospheric  and  electrostatic  discharges.  The  control 
board  207  has  succeeded  all  tests  concerning  the  electromagnetic  emissions  and  the  immunity  to  the  interference  as 
provided  by  the  European  rules  in  force.  It  conforms  to  the  directives  EMC  89/336/CEE,  92/31/CEE,  BT  73/23/CEE  and 
93/68/CEE 

 

 

 

Содержание 207-SM

Страница 1: ...to anyone who may need it and make sure that all involved personnel are aware of this Type of product The 207 control panel has been designed to control 1 or 2 operators 12VDC and a 24VDC version for...

Страница 2: ...circuit board 11 Automatic programming of working times and slowing speed 12 13 Manual programming of working times and slowing speed 14 Programming automation closing 15 16 Wireless Keypad Programmi...

Страница 3: ...dges are used on gates in all areas where a specific risk of trapping may occur especially where there is less than a 50cm gap behind a gate when fully open Resistor 8k2 ohm circuits are used where CA...

Страница 4: ...Output 24 VDCfor the flashing light 13 negative 14 positive 15 16 Output 24 VDC for accessories 15 positive 16 negative 17 18 Output 24Vdc for Motor 1 max 3A 19 20 Output 24Vdc for Motor 2 max 3A 21 2...

Страница 5: ...re to the slower Moving more to the faster 5 Dip Switches SW1 SW2 features S W 1 ON OFF 1 Working only with 1 motor Use input M1 Working with 2 motors M1 M2 2 Feature close immediately enable When the...

Страница 6: ...ant to store led DL6 switched off as confirmation that code has been stored You can store up to max 32 different codes for the Pedestrian 8 Remote control cancellation Cancellation of a single code st...

Страница 7: ...ansformer Cable Information Main Supply 230Vac 3 0Amp minimum Photocells Safety Edges and Viro Lock BT cable CW1128 with conduit recommended Motors 2 Core 1 5mm2 MIN With single motor SW1 1 needs to b...

Страница 8: ...tors have started the gate will not function If you are using two pairs of photocells as pictured the receivers should be crossed on opposite sides so that you do not have two receivers at the same si...

Страница 9: ...issioning to work One pair wiring FES 180 BIG 1 F Photocell Two pair wiring FES 180 BIG 1 F Photocell Remove this link when photocells are added The vertical jumpers should not be installed as the 909...

Страница 10: ...e power Turn the power back on again Press once the key fob that you previously learned in at step 2 and 3 Observe the direction that both gates move in at the start and then immediately turn the powe...

Страница 11: ...position The board automatically searches for the open gate position the gate for motor 1 opens and after 3 seconds fixed or preset delay the gate for motor 2 starts to open In order to protect the me...

Страница 12: ...ates move in at the start and then immediately turn the power off again The gate if that travels in an open direction is correct The gate that travels in a closing direction is incorrect Identify this...

Страница 13: ...ng press and release the P2 WORK the time between pressing WORK will determine the phase displacement interval for closing The door for motor 1 starts to close the LED flashes normally 16 Deceleration...

Страница 14: ...flash 2 Deleting automatic closing time Press and release the P1 BREAK button twice This sets the automatic closing waiting time to zero LED DL6 turns off PROGRAMMING RADIO CODE START CONTROL 1 Enter...

Страница 15: ...e 4 Dial in 00000 OK 99999 OK 5 5 Enter radio code programming for the START control On the 207C panel press and release the P3 button PROGR button The LED DL6 will start to flash Dial in the numbers...

Страница 16: ...5 5 Type in the new combination again 12345 6 To enter the code for the START control With the gate closed locate the P3 LEARN button and push the button once 7 While DL6 is flashing dial in the new c...

Страница 17: ...safety if necessary integrating those in the manual for installation of the door gate and give the user a copy Compile the proof book and give the user a copy see facsimile in Annex 1 Draft the EC de...

Страница 18: ...MACHINERY DIRECTIVE 98 37 EEC AND THE STANDARDS EN 13241 1 EN 12453 EN 12445 The risks listed below follow the sequence of the installation process These risks are those which are commonly present in...

Страница 19: ...force should be measured one leaf at a time Check that the values measured by the instrument are below those indicated in the graph Carry out the measurements in the following points L 50 300 and 500...

Страница 20: ...ective device in accordance with the standard EN 12978 for example a sensitive edge and repeat the measurement 5 Impact in the area of closure Figure 1 risk C F Install a pair of photocells recommende...

Страница 21: ...Use CE marked components and materials pursuant to the Low Voltage Directive 73 23 EEC F Carry out the electrical connections connection to the mains earth connections and relevant checks in accordanc...

Страница 22: ...afety devices installed 1 7 1 1 7 2 1 7 3 1 7 4 1 6 1 1 1 2 Integration principles for safety and information 20 Signalling equipment 21 Warnings 22 Marking 23 Operating instructions 23 Maintenance 24...