INSTRUCTIONS FOR USE
11/2010
- 43 -
NP-DK50 2V-5_04-2011_A
Fig.15
DK50 2V
1
Fig.14
MAINTENANCE
12. MAINTENANCE SCHEDULE
Maintenance that must be performed
Chapter
Time interval
Performed by
• Release condensate
Compressor without air drier
At high air humidity
Compressors with air drier
Compressors with condensation unit :
- from filter
- from pressure vessel
13.1
1 x week
1 x day
1 x week, check function
1 x week, check function
1 x week
operating staff
operating staff
operating staff
operating staff
operating staff
• Check safety valve
13.2
1 x year
qualified
technician
•
Replacement of the input filter and
prefilter
13.3
1 x every 2 years or after 4000 hours qualified
technician
• Replacement of filter in dryer
13.4
1 x year
qualified
technician
• Replacement of filter
in condensation unit
13.5
1 x year
qualified
technician
• Check tightness of joints
Overall examination of device
Service
documentation
1 x year
qualified
technician
13. MAINTENANCE
Repair work beyond normal maintenance can be performed only by qualified personnel or
the manufacturer’s representative.
Use only spareparts and accessories approved by the manufacturer.
Prior to any maintenance or repair work, switch off the compressor and disconnect it from
the mains (pull out the mains plug).
For permanently high efficiency of drying, it is necessary to maintain the whole appliance,
and mainly ventilator clean – regularly clean the surface of ventilator and cooling fins of
cooler.
TO ENSURE THAT THE COMPRESSOR WORKS CORRECTLY, PERFORM THE FOLLOWING
MAINTENANCE TASKS AT REGULAR INTERVALS (CHAPTER 12).:
13.1.
Condensation drain valve
Compressors
(Fig.14, Fig.15)
During regular use, release condensation from the pressure tank.
Switch off the compressor at the mains. Reduce air pressure in the
appliance to max. 1 bar by releasing air via a connected device. Place
the hose with the drain valve into a container prepared in advance (for
compressors DK50 2V/110 and DK50 2x2V/110 orientate the vessel
towards the
drain valve,
for compressors
DK50 2V place the vessel
under release valve) and open the drain valve (1). Wait until
condensation is fully drained from the pressure tank. Close drain
valve (1).
Compressors with condensation and filtration unit
(Fig.18)
During regular use, condensation is automatically released via the release
valve of the condensation unit filter. To check that the automatic drain is
working properly, open the valve (4) of the drain vessel (2) by turning to the
left. Release a small amount of condensate from the vessel. Close the
valve (4) by turning to the right.
Compressors with air dryer
In the case of a regular operation condensate is automatically excreted via
air dryer and it is entrapped in a bottle located at the housing side. Take out
the bottle from a holder, release blowing-out suppressor and pour out the
condensate.
If necessary, it is possible to connect the set for condensate discharge onto the condensate outlet
(see Chap. PARTS LIST - Auxiliary Equipment).
Содержание DK-50 2x2V/110
Страница 1: ......
Страница 2: ......
Страница 3: ...DK50 2V DK50 2V 110 11 2010 1 NP DK50 2V 5_04 2011_A OBSAH 2 CONTENTS 23 INHALT 44 Ed 5 ...
Страница 14: ...NÁVOD NA POUŽITIE NP DK50 2V 5_04 2011_A 12 11 2010 Obr 5 Kompresor s kondenzačnou jednotkou KJF Obr 6 Skrinka ...
Страница 15: ...NÁVOD NA POUŽITIE 11 2010 13 NP DK50 2V 5_04 2011_A Obr 7 Skrinka S110 ...
Страница 37: ...INSTRUCTIONS FOR USE 11 2010 35 NP DK50 2V 5_04 2011_A Fig 7 Box S110 ...
Страница 59: ...GEBRAUCHSANWEISUNG 11 2010 57 NP DK50 2V 5_04 2011_A Bild 7 Kasten S110 ...
Страница 85: ...SERVISNÝ MANUÁL SERVICE MANUAL SERVICEHANDBUCH 11 2010 83 NP DK50 2V 5_04 2011_A ...
Страница 105: ...ZÁRUČNÝ LIST GUARANTEE GARANTIEBRIEF 11 2010 103 NP DK50 2V 5_04 2011_A ...
Страница 106: ...DK50 2V DK50 2V 110 NP DK50 2V 5_04 2011_A 104 11 2010 ...
Страница 107: ...ZÁRUČNÝ LIST GUARANTEE GARANTIEBRIEF 11 2010 105 NP DK50 2V 5_04 2011_A ...
Страница 108: ......