CLEARANCES TO COMBUSTIBLES (continued)
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl
and embossed paper) positioned too close to the appliance may discolour or scorch.
VENTILATION
No purpose provided ventilation is normally required for this appliance.
The requirements of other
appliances operating in the same space or room, and the results of a spillage test must be taken into con-
sideration when assessing ventilation requirements, this will have been carried out by your CORGI registered
installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules in force.
FUEL BED LAYOUT
The appliance is supplied with 13 indi-
vidually wrapped hand-finished ceramic
pebbles and 1 combustion matrix.
1. Remove the combustion matrix from
its protective packaging, and position
onto the burner as shown. The letters ‘A
B C D’ should be facing forward.
2. Remove the pebbles from the protec-
tive packaging. On the bottom of the
pebbles are the letters A to M. You will
need to select the pebbles in alphabetic
order beginning with ‘A’.
Place the pebble ‘A’ onto the peg ‘A’ on
the matrix as shown.
3. Place the pebble ‘B’ onto the peg ‘B’ on
the matrix as shown. The pebble can only
fit onto the peg one way - do not force it
on.
4. Place the pebble ‘C’ onto the peg ‘C’
on the matrix as shown. When pebble ‘B’
is in position this pebble can only fit onto
the peg one way - do not force it on.
3.0
4.0
A
2.0
B
C
2
©
2009 Focal Point Fires plc.
Содержание eko 2030
Страница 2: ...Eko 2030...