TESTING FOR SPILLAGE (continued)
BRIEFING THE CUSTOMER
All instructions must be handed to the user for safekeeping.
Show the customer how to light and control
the fire
.
After commissioning the appliance, the customer should be instructed on the safe use of the appliance and
the need for regular servicing. Frequency of service depends on usage, but MUST be carried out at least one
annually.
Scratched and other superficial damage to the matt black paintwork of the appliance can be covered with
matching heatproof spray. Use only the manufacturers’ recommended spray paint. Paint only when the fire
is OFF and cold. Always mask off the surrounding area to prevent contamination with overspray. Ventilate
the room during the use of the spray.
DO NOT attempt to spray paint the pebbles or ceramics, or wash them in water.
SERVICING
Ensure that the fire is fully cold before attempting service. A suggested procedure for servicing is detailed
below.
1. Lay out the dust sheet and tools.
2. Carefully remove the ceramic components.
3. Check frame top for discolouration and signs of spillage.
4. Isolate the gas supply and disconnect the gas supply pipe. Remove the appliance shelf, control
knob and spindle, and the two screws securing the tray to the firebox.
5. Lift the burner tray from the firebox.
6. Remove the firebox as detailed in the relevant section.
7. Check the area behind the firebox for rubble accumulation and remove. If debris is excessive,
initiate remedial work on the flue.
8. Check the flue with smoke pellet for correct operation.
9. Re-fit the firebox using new seals where necessary.
10. Strip off the burner pipes and clean thoroughly.
11. Clean out the injector and pilot assembly. DO NOT attempt to dismantle the pilot unit.
12. Ensure the injector is aligned squarely with the venturi tube.
Re-assemble and re-fit the burner tray.
13. Re fit the control knob, spindle and appliance shelf and replace the ceramics, using genuine
spares where necessary.
14. Turn on the gas supply, and leak test.
15. Check any purpose provided ventilation is un-obstructed.
16. Light the fire and test for spillage.
17. Check setting pressure and safe operation of the appliance.
For specific servicing instructions, see the relevant sections.
10
14.5
14.6
15.0
C
C
B
A
Fireplace Opening
Smoke Match
In Tube
Match
Crimp
Tube
Cross section of smoke match tube
Make a smoke match tube from 10mm
diameter tube. Seal off one end and
crimp the tube to prevent the smoke
match from sliding down inside
.
A . 2 5 m m
down from
top of open-
ing
B. 25mm in
from front of
opening.
C. Disregard
outer 50mm
either side of
f i r e p l a c e
opening
©
2009 Focal Point Fires plc.