![EHP TELEBOX PLC Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/ehp/telebox-plc/telebox-plc_technical-manua_2368706043.webp)
Often, a malfunction or failure is caused by an operating error. If the device does not work properly,
first go through the points below. Sometimes the malfunction could be caused by another device.
Please check any additional devices that may be in use. The Telebox PLC works with error codes. We
have listed the error codes that you may be able to correct yourself. If you get an extended system
error that is not listed here, please contact the EHP service.
Problem
Remedy
The display shows "No."
The scale number was parameterized
incorrectly in the setup.
No function
Check the built-in fuse T1,6A
The display shows E xxxx (xxxx corresponds to
an error number)
Press the following key combination to
acknowledge the error:
Keep OK key pressed, ESC key also pressed,
NEXT. Error is acknowledged, if the error occurs
again, please work through the error code list.
E 1......9
Telebox SPS cannot be initiated.
SD card faulty or not formatted, short circuit on
an interface.
E 100
Faulty connection of the relay outputs or short-
circuit of the relay outputs.
E 1001
Faulty or invalid system state
E 1100, E1109...1117
Faulty radio protocol
E 1101
No start character included in the radio protocol
E 2301.......2322
Faulty Flash
E 3201, E 3202
Parameterization Telebox PLC, invalid
E 4001.....4008
IR processor error
E 5001
System clock time faulty, backup battery empty.
E 6000
SD card invalid, not formatted.
E 6001
SD card cannot be initiated.
E 6002
SD card not inserted
E 6003
SD card write protected
E 6010
Saved data set is lost
E 6101...6202
Read write error SD card