Configuration examples:
Example 1:
A 2t crane scale should be configured from 0 kg to 2000 kg on the 4-20 mA interface. 0 kg
corresponds to 4 mA, 1550, 5 kg corresponds to 20 mA.
Example 2:
A 30 t scale is to be configured to empty, 0 kg equals 20 mA, -30000 kg equals 4 mA.
Example 3:
A 5 t scale is to be configured from -5000 kg to +5000 kg. In addition, it is to be switched off
in the event of an overload. -5000 kg corresponds to 4 mA, +5000 kg corresponds to 20 mA.
Parameter
Sign (1.)
Weight before
decimal point (2.)
Weight after
decimal point (3.)
Value
P8
+
00000
.00
4
P9
+
01550
.50
20
Parameter
Sign (1.)
Weight before
decimal point (2.)
Weight after
decimal point (3.)
Value
P8
-
30000
.00
4
P9
+
00000
.00
20mA
Parameter
Sign (1.)
Weight before
decimal point (2.)
Weight after
decimal point (3.)
Value
P8
-
05000
.00
4
P9
+
05000
.00
20mA
In addition, assign the relay output pin 3, overload, via a relay to the PLC.