Byte # ASCII
Meaning
7.
Digit 2
Decimal place of the weight
8.
Digit 1
Units digit of the weight specification
9.
B
N
Scale tare OFF (gross weight)
Scale tare ON (net weight)
10.
E
1
2
Single range scale
in area I
in area II
11.
0
1
No standstill
Standstill
12.
0
1
2
3
4
5
6
7
8
A
X
E
C
No key is pressed on the handheld transmitter
Key 2 (Print key)
Key 4 (Add- key)
Key 6 (Total key)
Scale was switched off manually
Scale was switched off by automatic switch-off function
Reception disturbance
Test
13.
V
H
L
Accumulator of the scale charged
Accumulator of the scale - forewarning
Balance accumulator - Discharged/ Empty
14.
(1 - 99)
Digit 1 of the scale number
15.
(1 - 99)
Digit 2 of the scale number
16.
(X)
no setpoint =0, setpoint 1 =8
Setpoint 2=4, Setpoint 3=2
Setpoint 4=1 Values of the setpoints that overlap are added
together.
17.
N
J
G
No overload
Overloaded
Preload too high