![EHP TELEBOX PLC Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/ehp/telebox-plc/telebox-plc_technical-manua_2368706027.webp)
The RS-232 interface may only be connected in a voltage-free state.
Non-observance can lead to the destruction of the V24 interface!
Either the RS-232 or the RS-485 interface can be used. Simultaneous operation of both
interfaces is not possible. Please note the parameterization of parameter 3.
The data output of the interface is controlled via parameter 5.
0 = No data sets to the RS 232 interface, data from the flash is sent directly to the RS 232
interface on request.
1 = Data records are forwarded continuously to the RS 232 interface.
2 = Only data records containing control characters Print/Add/Tara are forwarded to the RS
232 interface.
There are 2 different data protocols available. Data protocol 1 corresponds to the data
record of the balance. The length varies according to the data protocol that is set in the
scale.
Data protocol 0 corresponds to the classic Telebox-Plus format and does not vary in length.
This protocol type is not recommended for new projects.
Data log 1, 28 byte data log (parameter 7=1)
The extended data protocol (28 bytes) has the following data format and is preset in the
delivery state. This is the original protocol of the scale.
Byte # ASCII
Meaning
1.
S
Start signal
2.
0
1
2
3
4
No comma
One decimal place
Two decimal places
Three decimal places
Four decimal places
(e.g. 19520)
(e.g. 1952.0)
(e.g. 195.20)
(e.g. 19,520)
(e.g. 1.9520)
3.
Blank
(20H)
+
-
No sign
Plus
Minus
4.
Digit 5
Ten-thousandths digit of the weight
5.
Digit 4
Thousands digit of the weight
6.
Digit 3
Hundreds digit of the weight