HERE
gives to the control console
1202
the
zone number 1 (the console needs a zone number
only if it must be ready to receive messages).
ZONE SET
When pressed, the system is ready
to assign number 1 to a zone, and all the "zone
set" led lamps of the devices which can be given
a zone number will blink. If, in the mentioned
devices, one of the
ZONE SET
buttons is pressed,
that specific device will be identified as
ZONE
NR. 1
, and the system will get ready to assign
number 2 to the following device / zone.
Control console 1202. Advanced functions
1202
If the general access password is active the system will require us to introduce it every time
we try to operate one of the advanced functions (see point 2 of access restrictions).
Control console 1202. Advanced functions
1202
If the general access password is active the system will require us to introduce it every time
we try to operate one of the advanced functions (see point 2 of access restrictions).
1202
Control console
4
Labelling groups with names
If one group has already been created:
GR 01
(And then the sign <
appears next to
GR 01) +
If the general access password is NOT
active:
NAME
>>>
(the cursor is placed in letter
"R"
)
+
(
"
R"
is replaced by
"Q"
)
+
5
Assigning a zone to a group
If one group has already been created:
GR 01
(And then the sign <
appears next to
GR 01
)
+
If the general access password is NOT
active:
ZONES
Provided that there are 3 numbered
zones in the system and zone number 2
belongs to group number 1.
ZON 001 +
ZON 002
Now zone number 1 belongs to group
number 1 and zone number 2 does not.
6
Changing the order of appearance of
groups in the screen
If three groups -for instance- have been
previously created:
GR 01
(And then the sign <
appears next to
GR 01
)
+
If the general access password is NOT
active:
CHANGE
GR 03
Now it is recommended to initialise the
system again (like in point number
13
) so
that the system checks again the
relationships between groups and zones.
7
Erasing a group
If three groups -for instance- have been
previously created:
GR 03
(And then the sign >
appears next to
GR 03
)
+
If the general access password is NOT
active:
ERASE
YES
1
Giving a number to each zone
2
Labelling the zones with names
3
Creating a group and giving it a number
By following this procedure we can give
consecutive numbers to all the zones of the
installation without going back to the console
1202 (this is useful for the initial configuration
of the installation).
It is also possible to select a specific zone number
by pressing
+
or
and, after pressing
ZONE SET
and following the
ZONE SET
button of
the corresponding device, the selected number will
be given to that device (this is useful to replace an
old device by a new one whivh must have the same
number without repeating the set up procedure).
When a zone number has been assigned to all the
zones of the installation, we will quit the labelling
procedure and all the
ZONE SET
led lamps of the
different devices will stop blinking.
Now it is recommended to start up the system (point
nr.
13
) prior to label the zones with names.
If NO groups have been created yet:
GENERAL
(and the sign "<" appears
next to
GENERAL)
+ ZONE
If three zones -for instance- have been
previously created:
ZON 001
(and the sign "<" appears next
to
ZON 001)
+
If the general access password is NOT active:
NAME
>>>
(the cursor is placed in letter
O
) +
+
(
O
is replaced by
P
) +
If NO groups have been created yet:
GENERAL
(and the sign "<" appears
next to
GENERAL)
+
If the general access password is NOT active:
NEW
YES
40
SETUP
ZONES
here
zone set
000 +
If the general access password is
NOT
active
and there is NEITHER a prerecorded message
player (
1103
) NOR a module for sending
messages over the telephone (
1104
) in the system:
This is the first thing that has to be done in order
to configure a system (and it does not have to
be done again if the system configuration is not
modified).
Provided that no groups have been created yet:
time
lang.
t-phone
message
bell
more
zones
here
set zone
000 +
ZONE SET
cancels all the numbers that have
been given to the zones until pressed.
+
here
set zone
002 +