Table 10.3 Safety Functions
Abnormality
/Error
Operation state
of safety
functions
Lamp
indication
LCD
REMOTE
output signal
State of the STP pump
Probable causes of an
abnormality/error
Reset by
RESET
operation
Power failure Power failure
time: 2 seconds
or longer.
"FAILURE"
lights.
"POWER"
goes out.
"POWER
FAILURE"
"ALARM"
"POWER ON"
output cut-off
The magnetic bearing
continues to operate
using regenerative
energy.
The STP pump
decelerates and stops.
The rotor lands on the
touch down bearing at
approx. 17,000 rpm.
Power failure.
Power cable breakage.
Power cable
disconnection.
Impossible
Abnormal
magnetic
bearing
Rotor descends
onto the touch
down bearing.
"FAILURE" "DISTURBANCE"
"ALARM"
The rotor stops on the
touch down bearing.
STP connection cable
breakage.
STP connection cable
disconnection.
Abnormal control circuit.
Possible
Excessive
vibration
Rotor vibration:
100
µ
m 0-P or
more.
"FAILURE" "DISTURBANCE"
"ALARM"
The STP pump
decelerates and stops.
External vibration, and
impact.
Intrusion of atmospheric
air.
Intrusion of foreign
particles.
Possible