STP-301/451 Series Instruction Manual
4-9
Installation
4.3.3
How to Secure the STP Pump
◇
The STP pump is provided w ith a high-speed rotor. The w orst-case failure may
result in a jump in rotational torque leading to personal injury or peripheral
equipment damage.
The method of securing the STP pump w ill depend on the installation
requirements. Secure the STP pump to the vacuum equipment as follow s:
◇
Design and secure the mounting for the STP pump so that it can w ithstand the
maximum rotational torque. Refer to Table4.2 for torque in pump abnormality.
◇
In some cases, the damper and the claw clamper securing cannot be used
depend on the type of the STP pump.
◇
Refer to Table 4.1 for tightening torque of the bolt.
Table 4.1 Tightening torque of bolt
Size of bolt
Tightening torque of bolt (Nm)
M8 12.0
M10 24.1
M12 42.1
◇
When making the leg to secure the base, make them shortened more than ones
attached to the STP pump.
Use a material that has a tensile strength of 600N/mm
2
or more.
◇
When securing the base, use stainless steel securing bolts w ith a tensile
strength class is 70 or more.
◇
When using any securing method other than that specified in this manual, contact
BOC Edw ards.
Damper
Yes
No
with bolts
with Claw Clamps
Secure the inlet
Refer to "1)
When securing
the inlet port w ith bolts
"
Refer to "2)
When securing
the inlet port flange w ith
claw clamps
"
Refer to "3)
When installing
the damper in the inlet port
flange
"