Installation
6.3
Attaching the STP Control Unit Front Panel to a Rack
The dimensions of the STP control unit front panel conform to EIA Standard.
Therefore, this panel can be attached to any type of commercially-available racks.
Attach the front panel unit to the rack according to the following steps:
•
Attach the front panel to a rack using the screw holes for the front panel.
•
Also support the STP control unit from the bottom using a support angle or a
similar tool.
•
To protect the STP control unit during transport, remove the rubber foot from
the bottom and attach the STP control unit to the rack using the screw holes for
the rubber foot.
◇
The STP control unit cannot be supported w ith only the screw s on the front
panel (the STP control unit is a heavy product).
Alw ays support it from the bottom.
◇
When installing the STP control unit, DO NOT block the ventilation port of the STP
control unit by the support angle or other things. It causes the control unit to
overheat.
◇
For the dimensions of the front panel and positions of screw holes for the rubber
foot, see Figure13.5, "External Appearance of the STP Control Unit."
Support Angle
Part: Secure with screw
Figure 6.6 Example of Securing the STP Control Unit
Содержание STP-301 Series