Door Release Time
Three different settings:
Door release time (1 to 255 seconds)
The amount of time the door is open if a valid card is used.
Extended time (1 to 255 seconds)
Allow individual cardholders to have the door open for a longer
period of time e.g. disabled or elderly people.
Request to Exit (1 to 255 seconds)
This time can be individually set and is often set longer when the
REX is used at the reception allowing visitors a slightly longer
entry time.
When the REX button is used, the reader fitted outside can be set to sound twice to indicate the door has been
released for visitors. This feature is particularly useful when used with magnet locks since their operation is
totally silent.
Start-up Mode Settings
The start-up mode setting enables you to determine how the door operates in case of total power failure,
including exhaustion of the battery back up. All the data is stored permanently in the controller for up to 100
years without the need for any power, and upon power-up will continue to operate without the need for a
database download.
High security mode
Only cardholders with the high security mode enabled will have access.
Normal mode
Returns to normal mode from whatever the status was prior to power failure.
Door unlocked
The door unlocks permanently until a valid card with the unlock feature is used
twice, or the door is changed to normal mode from the PC.
Last known mode
This will return to the status the door was set to prior to power failure.