
C
HAPTER
2
| Initial Switch Configuration
Basic Configuration
– 42 –
The switch includes an SNMP agent that supports SNMP version 1, 2c, and
3 clients. To provide management access for version 1 or 2c clients, you
must specify a community string. The switch provides a default MIB View
(i.e., an SNMPv3 construct) for the default “public” community string that
provides read access to the entire MIB tree, and a default view for the
“private” community string that provides read/write access to the entire
MIB tree. However, you may assign new views to version 1 or 2c
community strings that suit your specific security requirements (see
“Configuring SNMPv3 Views” on page 140
).
C
OMMUNITY
S
TRINGS
(
FOR
SNMP
VERSION
1
AND
2
C
CLIENTS
)
Community strings are used to control management access to SNMP
version 1 and 2c stations, as well as to authorize SNMP stations to receive
trap messages from the switch. You therefore need to assign community
strings to specified users, and set the access level.
The default strings are:
◆
public
- with read-only access. Authorized management stations are
only able to retrieve MIB objects.
◆
private
- with read/write access. Authorized management stations are
able to both retrieve and modify MIB objects.
To prevent unauthorized access to the switch from SNMP version 1 or 2c
clients, it is recommended that you change the default community strings.
To change the read-only or read/write community string, type either of the
following commands, and press <Enter>.
“snmp read community
string
”
“snmp write community
string
”
where “string” is the community access string.
>snmp read community rd
>snmp read community
Read Community : rd
>
N
OTE
:
If you do not intend to support access to SNMP version 1 and 2c
clients, we recommend that you delete both of the default community
strings. If there are no community strings, then SNMP management access
from SNMP v1 and v2c clients is disabled.
Содержание ES4528V-38
Страница 1: ...Management Guide www edge core com 28 Port Gigabit Ethernet Switch...
Страница 2: ......
Страница 4: ......
Страница 6: ...ABOUT THIS GUIDE 6...
Страница 22: ...FIGURES 22...
Страница 26: ...SECTION Getting Started 26...
Страница 46: ...CHAPTER 2 Initial Switch Configuration Managing System Files 46...
Страница 48: ...SECTION Web Configuration 48...
Страница 75: ...CHAPTER 4 Configuring the Switch Creating Trunk Groups 75 Figure 11 LACP Port Configuration...
Страница 135: ...CHAPTER 4 Configuring the Switch Simple Network Management Protocol 135 Figure 34 SNMP System Configuration...
Страница 186: ...CHAPTER 6 Performing Basic Diagnostics Running Cable Diagnostics 186...
Страница 191: ...CHAPTER 7 Performing System Maintenance Managing Configuration Files 191 Figure 72 Configuration Upload...
Страница 192: ...CHAPTER 7 Performing System Maintenance Managing Configuration Files 192...
Страница 242: ...CHAPTER 12 Port Commands 242...
Страница 248: ...CHAPTER 13 Link Aggregation Commands 248...
Страница 266: ...CHAPTER 15 RSTP Commands 266...
Страница 276: ...CHAPTER 16 IEEE 802 1X Commands 276...
Страница 286: ...CHAPTER 17 IGMP Commands 286...
Страница 294: ...CHAPTER 18 LLDP Commands 294...
Страница 300: ...CHAPTER 19 MAC Commands 300...
Страница 310: ...CHAPTER 21 PVLAN Commands 310...
Страница 322: ...CHAPTER 22 QoS Commands 322...
Страница 356: ...CHAPTER 26 SNMP Commands 356...
Страница 359: ...CHAPTER 27 HTTPS Commands 359 EXAMPLE HTTPS redirect enable HTTPS...
Страница 360: ...CHAPTER 27 HTTPS Commands 360...
Страница 366: ...CHAPTER 29 UPnP Commands 366...
Страница 374: ...CHAPTER 31 Firmware Commands 374...
Страница 376: ...SECTION Appendices 376...
Страница 390: ...GLOSSARY 390...
Страница 394: ...INDEX 394 W web interface access requirements 49 configuration buttons 50 home page 50 menu list 51 panel display 51...
Страница 395: ......
Страница 396: ...ES4528V E072009 ST R01 149100000014A...