Instruction manual for ECOSOFT Robust reverse osmosis system
|
12
This manual is the intellectual property of, and copyrighted by ECOSOFT SPC LLC. Copying and reprinting is forbidden. © 2015
compression nut back on till snug. Connect the
other end of red tube to the inlet port of the RO
system’s port rack.
Push tube all the way to the tube stop when
making push-fit connections.
5
Drain saddle
6
fits most standard drain pipe.
Install the drain saddle on drain pipe as follows. Bore
5 mm hole in the drain pipe, apply rubber gasket with
sticky base (included in the package). Install drain saddle
on top of the gasket so that push-fit fitting in the saddle
is located precisely above the hole in drain pipe. Tighten
nuts on drain saddle fasteners with a wrench. Insert
black tube in the push-fit fitting in drain saddle. Connect
the other end of black tube with drain port of the RO system’s push-fit port rack.
6* Put a few turns of PTFE tape on tank nipple thread.
Screw tank valve on the tank nipple. Turn the valve fully
off.
NOTE!
Test air pressure in the empty tank bladder
(remove cap on the lateral bottom to access valve
stem). Reading should be as specified in p. 2.1. If
necessary, use air pump with to inflate the bladder. If
pressure is too high already, push on the valve stem’s
core to relieve it.
7
Install the faucet
7.1 To install purified water faucet
8
bore a
12,5 mm diameter hole in desired
location on sink or countertop.
Caution!
Metal shavings can damage
your sink, remove them carefully once
you have finished drilling. If the
mounting surface is stone or ceramic,
use a carbide drill bit
7.2 Mount the faucet over the hole on top
of small rubber washer, chrome plated
base, and large rubber washer. Fix the
faucet firmly with plastic washer, lock
washer, and nut put on the faucet
shank underneath sink surface.
7.3 Put compression nut on free end of
Содержание Robust