Instruction manual for ECOSOFT Robust reverse osmosis system
|
19
This manual is the intellectual property of, and copyrighted by ECOSOFT SPC LLC. Copying and reprinting is forbidden. © 2015
7
Put a chlorine tab in the first prefilter bowl. Fill to the top with water and screw
back on.
8
After 15 minutes, open pressure tank valve. Leave purified water faucet closed.
9
Provide power to the system, then open feed water valve for 5 minutes.
10 Close pressure tank valve and let stand for 1-2 hours.
11 Open purified water faucet and drain all chlorinated water from the tank by
opening purified water faucet.
Open feed water valve and flush the system until chlorine smell disappears.
Close feed water valve and remove power from the system.
Disconnect permeate collector tube from the 2
nd
filter housing outlet and
reconnect it back to the tee. Connect high pressure pump feed tube back to 2
nd
prefilter housing. Check that the original tubing is restored properly.
12 Install filters back in housings, then open feed water valve and provide power to
the system again.
13 Refill and drain a few tankfuls of water (until chlorine smell disappears
completely).
* Skip if your system is not equipped with a pressure tank
Содержание Robust
Страница 1: ...ECOSOFT Robust Reverse osmosis system Installation and operation manual...
Страница 28: ......