background image

MAINTENANCE

Periodic maintenance is required to insure that the Breeze

AT

operates properly. A

severely polluted environment can foul a purifier plate in as little as two weeks,
normal plate cleaning should take place monthly. Shown here are basic procedures
that should be carried out to keep your unit running at top performance.

CAUTION: Unplug the Breeze

AT

before performing any maintenance procedures.

Cleaning the Case:

Wipe the Breeze

AT

with a soft cloth dampened with water. Do not use chemicals or

solvents. Vacuum the front grill periodically to remove any lint buildup. 

Rear lint-screen / filter cleaning:

You have two options to clean the lint screen:

• When visibly dirty, simply remove the rear filter  from the  Breeze

AT

and, with a

hand-held vacuum, remove the heavy particulate from the filter. This method will
extend the life of the filter. 

OR

• When visibly dirty, remove the rear filter from the Breeze

AT

and wash in hot water,

brushing gently with a toothbrush to remove particulate. Allow to dry prior to re-
installing the lint screen. Note: do not use soap - it will damage the carbon
material in the lint screen / filter.

Rear lint-screen / filter replacement:

Contact your EcoQuest Dealer for replacement filters.

Purifier Plate:

Remove the rear filter (see page 5). Carefully remove the Ecotech purifier plate
from the card cage by grasping the middle of the edge nearest to you, (See page 6
for purifier plate location) and slowly  pull it straight out.

Clean the purifier plate with hot water and ammonia. Dry completely using a hair
dryer if necessary. Reinstall purifier plate (See page 6) . Be sure to check that the
electrical tabs are in contact with the plate.

Purifier Plate Card Cage:

Also be sure to clean the white stand-offs at the corners of the purifier plate card
cage. (A cotton swab with alcohol works well.)

Changing the fuse:

The fuse may be accessed by unplugging the cord from
the back of the unit and gently pulling the fuse holder
straight out. Replace with a 1amp buss type fuse only.

Fuse Location

10

Содержание Breeze AT

Страница 1: ...65 00085 003 REV 1203 Breeze SP ENG OM 12_03 ...

Страница 2: ...lation Inspection 4 Unit Features 5 Remote Features 5 Manual Controls 6 Rear Access Filter 6 Ecotech Purifier Plate Installation 7 Placing the Unit 7 Setting Adjusting Controls remote 8 Setting Adjusting Controls manual 9 Maintenance 10 Troubleshooting 11 Warranty 12 Please record the serial number of your BreezeAT Serial ______________________________________________ Please record the name and ph...

Страница 3: ...ation depending on model 30 watts power consumption 24 to 30 KV 20 30 Khz ion generation pulsator Fixed 6 KV DC needle ion generator Mechanical 400 CFM fan Size Dimensions 11 75 x 8 x 9 75 Weight 16 pounds Ozone Output 0 340 mg per hour Coverage Covers a range of 20 square feet to 2 500 square feet Depends on variables such as severity and frequency of pollution humidity and temperature Warranty B...

Страница 4: ...l processes The BreezeAT also includes a feature which will effectively sanitizes an unoccupied area PRE INSTALLATION AND INSPECTION 1 Open and remove shipping corners from top of carton 2 Remove parts box from carton 3 Remove unit from shipping carton 4 Remove all protective materials 5 Check for shipping damage and loose or broken parts 6 Read Owners Manual thoroughly prior to installation 7 Rem...

Страница 5: ...ote Control or Manual Operation Portable Computer style cord Uses Standard 100 110 220 or 240 volt household current depending on model No Chemicals Necessary Carbon impregnated lint screen Washable Ecotech Purification Plate Low Maintenance Purifier Fan Purifier Fan Purifier On Off Power Sanitize POWER ON OFF Sanitizer ON Battery compartment 2 AAA Purifier ON OFF Purifier DOWN Purifier UP Fan UP ...

Страница 6: ...fier DOWN Fan DOWN Purifier ON OFF CAUTION UNPLUG UNIT BEFORE SERVICING NOTE 110V MODEL DOES NOT USE LINT SCREEN CLIP SKIP TO STEP 3 FOR MODELS WITHOUT CLIP 1 Loosen 2 screws securing clip at top center of lint screen 2 Slide clip up 3 Gently pull top of lint screen out of unit 4 Once the top is out of the unit pick straight up on the lint screen to remove 5 Reassemble in reverse order 1 2 3 4 ...

Страница 7: ...talled correctly PLACING THE UNIT Place the unit as high as possible to insure complete purification On top of a bookshelf high cabinet etc Suggested locations listed in the order of preference 1 Nearest the source of the worst pollution 2 Near a cold air return to thoroughly circulate clean air throughout the area 3 In the area most heavily used to achieve maximum benefit Note The rear of the uni...

Страница 8: ...lue lights on the front of the unit until achieving the desired level Purifier Control Set the purifier to approximately 40 2 LEDs lit Adjust the purifier control up or down after one hour based on the following criteria 1 The chart shows the correct purifier level for the square footage of the environment Under normal conditions it is not necessary to adjust the purifier control above the square ...

Страница 9: ... should adjust the level according to personal preference but not exceeding the level recommended above for the square footage of the area SETTING AND ADJUSTING CONTROLS MANUALLY The BreezeAT can also be adjusted using the buttons located on the front of the unit The buttons correspond to the buttons on the remote POWER FAN UP FAN DOWN PURIFIER ON OFF etc so operation and set up are the same for b...

Страница 10: ...zeAT and wash in hot water brushing gently with a toothbrush to remove particulate Allow to dry prior to re installing the lint screen Note do not use soap it will damage the carbon material in the lint screen filter Rear lint screen filter replacement Contact your EcoQuest Dealer for replacement filters Purifier Plate Remove the rear filter see page 5 Carefully remove the Ecotech purifier plate f...

Страница 11: ...or broken the purifier plate s will require replacement Ensure maintenance procedures required for the purifier plate s have been performed according to the Maintenance section of this Owner s Manual Order new plates from your EcoQuest Dealer Electrical stainless steel contacts are not contacting the screen portion of the Purifier plate s Unplug and inspect the unit for any loose connections Do no...

Страница 12: ...g trouble shooting contact your EcoQuest Dealer for further assistance contact EcoQuest at the address located on the front of the manual or visit www EcoQuest com for additional technical support WARRANTY INFORMATION This product is of solid state construction and is warrantied by EcoQuest International 310 T Elmer Cox Drive Greeneville TN 37743 to the original purchaser depending on model to be ...

Отзывы: