14.6.3 Pin assignment / conductor coloring connector III (4-terminal)
Connector for empty report, fault and stroke signal output:
Pos.
Conductor
coloring
Assignment
1
brown
Output low level warning, empty report, fault (+)
2
white
Output low level warning, empty report, fault (-)
3
blue
Output stroke signal (+)
4
black
Output stroke signal (-)
Chapter 7.2.3 ‘Connector assignment of slot II (5-terminal) Input
for pulse signal, standard signal, metering lock, batch and metering
WARNING!
At 115V/230 V, a simultaneous connection of contact 1+2 (alarm output) and
3+4 (stroke signal output) is generally not permitted.
14.7
Metering rates
Repeatable metering accuracy is approx. ± 3 % at minimum 30 % stroke length and
otherwise constant conditions. In order to balance the clearance, the stroke length
adjustment has to be based on the lower value towards the desired stroke length (= sense
of rotation to the right).
Due to the characteristics of the pump, higher output can be produced until the operating
temperature is reached.
Precise metering can be achieved provided the following items are adhered to:
n
All metering-rate data is referred to measurements using water at 20° C, constant
supply voltage and the metering pump at operating temperature. The factory setting
for the metering rate (= setting accuracy) at a maximum metering back-pressure is
+ 5 - 15 % of the rated value.
n
A pressure-maintenance valve (or metering valve) for generation of the most constant
possible counter pressure of not less than 0.005 MPa (0.5 bar) should be used in
order to obtain high metering accuracy in case of metering with unobstructed
discharge.
n
If there is pre-pressure on the suction side, the pressure difference between the
suction and the pressure sides must be at least 0.1 MPa (1 bar). The water column on
the metering pump must be protected by an appropriate valve arrangement.
NOTICE!
A pressure control valve or a metering value is not an absolutely hermetically
sealing shutoff device.
WARNING!
Dosierhubverstellung nur bei laufender Pumpe, wenn Hubeinstellschraube
entlastet ist.
Technical Specifications
128
417101442 Rev. 12-02.2019
Содержание Elados EMP KKS E60
Страница 2: ......
Страница 123: ...14 2 Abmessungen Abb 89 Abmessungen Technische Daten 121 417101442 Rev 12 02 2019 ...
Страница 134: ...16 Konformitätserklärung Abb 95 Konformitätserklärung Konformitätserklärung 132 417101442 Rev 12 02 2019 ...
Страница 135: ......
Страница 258: ...14 2 Dimensions Fig 90 Dimensions Technical Specifications 122 417101442 Rev 12 02 2019 ...
Страница 269: ...16 Declaration of Conformity Fig 96 Declaration of Conformity Declaration of Conformity 133 417101442 Rev 12 02 2019 ...
Страница 393: ...14 2 Dimensions Fig 93 Dimensions Données techniques 123 417101442 Rev 12 02 2019 ...
Страница 404: ...16 Déclaration de conformité Fig 99 Déclaration de conformité Déclaration de conformité 134 417101442 Rev 12 02 2019 ...
Страница 405: ......