12
Operating faults
12.1
Metering warning messages (display)
Display Meaning
Effect
Cause
Remedy
reserve report
(flashing)
pump continues
running
low-level advance
warning active
Refill the metering
medium
Operating faults: Metering warning messages (display): reserve report
empty report
pump is stopped
empty report active
Refill the metering
medium
Operating faults: Metering warning messages (display): empty report
metering lock (only
possible if this is
configured)
pump is stopped
no external enable of
the pump
Activate external
enable or deactivate
the metering lock in the
configuration menu.
(
Operating faults: Metering warning messages (display): metering lock
Indicator in operation
mode 4..20 mA flashes
standard signal
monitoring responds
pump is stopped
standard signal is
under 3mA or cable to
standard signal
connection is broken
check the standard
signal or cable
Operating faults: Metering warning messages (display): standard signal monitoring
--.-
standard signal is
above 23 mA
pump runs in
continuous operation
standard signal
exceeds the display
range
reduce the standard
signal
Operating faults: Metering warning messages (display): standard signal is above 23.0 mA
Operating faults
112
417101442 Rev. 12-02.2019
Содержание Elados EMP KKS E60
Страница 2: ......
Страница 123: ...14 2 Abmessungen Abb 89 Abmessungen Technische Daten 121 417101442 Rev 12 02 2019 ...
Страница 134: ...16 Konformitätserklärung Abb 95 Konformitätserklärung Konformitätserklärung 132 417101442 Rev 12 02 2019 ...
Страница 135: ......
Страница 258: ...14 2 Dimensions Fig 90 Dimensions Technical Specifications 122 417101442 Rev 12 02 2019 ...
Страница 269: ...16 Declaration of Conformity Fig 96 Declaration of Conformity Declaration of Conformity 133 417101442 Rev 12 02 2019 ...
Страница 393: ...14 2 Dimensions Fig 93 Dimensions Données techniques 123 417101442 Rev 12 02 2019 ...
Страница 404: ...16 Déclaration de conformité Fig 99 Déclaration de conformité Déclaration de conformité 134 417101442 Rev 12 02 2019 ...
Страница 405: ......