11.1
Austausch von Saug- / Rücklauf- und Druckventil
Fig. 86: Replacing the suction / return valve
1.
Disassemble suction valve and pressure valve (pos. 5/7) with a crescent wrench
(SW 22).
2.
Assemble all the O-rings.
3.
Screw in the suction valve and pressure valve in the correct position
(torque of 2-3 Nm).
NOTICE!
Please observe, that the valve spring (pos. I), valve-ball (pos. II) and the o-ring
(pos. III) are not lost and installed in the right direction at the pressure valve.
Pos. Description
A
CONNECTION SET
1
Union nut
2
Clamping piece
3
Tapered part
B
SUCTION-/RETURN VALVE
4
O-Ring, Ø 10 x 2,5
5
Suction-/Return valve
6
O-Ring, Ø 14 x 2,5
C
ANGLE CONNECTION
D
PRESSURE VALVE
4
O-Ring, Ø 10 x 2,5
6
O-Ring, Ø 14 x 2,5
7
Pressure valve (pressure line)
I
Valve spring
II
Valve-ball
III
O-Ring, Ø 12 x 1,5
Maintenance
108
417101442 Rev. 12-02.2019
Содержание Elados EMP KKS E60
Страница 2: ......
Страница 123: ...14 2 Abmessungen Abb 89 Abmessungen Technische Daten 121 417101442 Rev 12 02 2019 ...
Страница 134: ...16 Konformitätserklärung Abb 95 Konformitätserklärung Konformitätserklärung 132 417101442 Rev 12 02 2019 ...
Страница 135: ......
Страница 258: ...14 2 Dimensions Fig 90 Dimensions Technical Specifications 122 417101442 Rev 12 02 2019 ...
Страница 269: ...16 Declaration of Conformity Fig 96 Declaration of Conformity Declaration of Conformity 133 417101442 Rev 12 02 2019 ...
Страница 393: ...14 2 Dimensions Fig 93 Dimensions Données techniques 123 417101442 Rev 12 02 2019 ...
Страница 404: ...16 Déclaration de conformité Fig 99 Déclaration de conformité Déclaration de conformité 134 417101442 Rev 12 02 2019 ...
Страница 405: ......