48
e) Status indicator
With the help of the special ‘status indicator’ function, the following parameters can be retrieved for the room controller:
• Actual temperature
• Security code
To access the status indicator, proceed as follows:
• Briefly press the ‘
x
’ button once.
• Select ‘Sonderfkt.’ (special function) using the scroller.
• Briefly press the ‘
x
’ button once.
• Select ‘H-Regler’ (H controller) using the scroller.
• Briefly press the ‘
x
’ button once.
• Select ‘Statusanz.’ (status indicator) using the scroller.
• Briefly press the ‘
x
’ button once.
• By turning the scroller, you can ‘browse’ a list of all the available room controllers.
The display shows the following:
• To the right: Current room temperature or ‘---’ for a reception failure
• To the left: Security code of the room controller as well as ‘H 1’, ‘H 2’, etc.
‘H 0’ stands for the control centre itself, while ‘H 1’, ‘H 2’, etc., stand for the room controllers
• Lower display line: Name of the room
f) Alarms
X
X
X
X
X
1. Alarm triggers/alarm priorities
When malfunctions occur, the FHZ1000 generates alarm signals.
Alarm signals are updated every 10 minutes, which means that the maximum amount of time until an alarm is signalled
or reset by the FHZ1000 is 10 minutes. A total of 4 alarm signals can be displayed. These are:
•
‘
Batterie
’
(battery)
A component’s battery is empty.
•
‘
Untertemp
’
(low temp)
The target temperature cannot be reached in a room.
•
‘
K. Empfang
’
(no reception)
One or more room controllers or the alarm dialler cannot be received any longer; the wireless connection is down.
• ext-Alarm
This option is reserved for later applications that are not currently active; no function.
Ö
The alarm signal occurs acoustically with a tone signal as well as on the display.
When an alarm is issued an exclamation mark appears in the lower left corner of the display.
FHT 8W Heat Demand Relay
Installation and User Guide
Product Code EHC-FH06
1