13
Setup Option Level 1 Level 2 Level 3
Function
MOd
Select module s/n [NONE]
RATE
Set display update rate [FAST]
AOUT A1 (upper channel)
Program analog output 1 [NH3,0,2000]
A2 (upper channel)
Program analog output 2 [VH,0,15.00]
A3 (upper channel)
Program analog output 3 [P,0,500]
A4 (lower channel)
Program analog output 4 [NH3,0,2000]
A5 (lower channel)
Program analog output 5 [VH,0,15.00]
A6 (lower channel)
Program analog output 6 [P,0,500]
dISP P1 (upper channel)
Program upper display parameter P1 [RPVS]
P2 (upper channel)
Program upper display parameter P2 [VHCM]
P3 (upper channel)
Program upper display parameter P3 [VSW]
P4 (upper channel)
Program lower display parameter P4 [VH]
P5 (upper channel)
Program lower display parameter P5 [VS]
P6 (upper channel)
Program lower display parameter P6 [P]
P7 (upper channel)
Program lower display parameter P7 [TEMP]
P8 (lower channel)
Program upper display parameter P8 [RPVS]
P9 (lower channel)
Program upper display parameter P9 [VHCM]
P10 (lower channel)
Program upper display parameter P10 [VSW]
P11 (lower channel)
Program lower display parameter P11 [VH]
P12 (lower channel)
Program lower display parameter P12 [VS]
P13 (lower channel)
Program lower display parameter P13 [P]
P14 (lower channel)
Program lower display parameter P14 [TEMP]
CAL NH3
ZERO
Calibrate NH
3
sensor zero
SPAN
Calibrate NH
3
sensor span
FACT
Reset NH
3
sensor (zero and span) to factory calibration for NH
3
P
UNIT
Choose pressure units [KPA]
N, C
Enter pressure sensor calibration numbers
AVG
NH3
Program NH
3
averaging [0.375]
P
Program Pressure averaging [0.375]
SKEW NH3
Program gain and offset modifier [1,0]
P
Program gain and offset modifier [1,0]
CONF LEdS
Set display intensity [3333]
1V4V
Check analog outputs at 1V and 4V
CAN
IdS
Program CAN addresses and produce .dbc file [1~5]
RATE
Program CAN transmit rate [5 ms]
BAUd Program CAN baud rate [500k]
LOCK
Lock display
FACT
RST
Reset analyzer to factory defaults (see “[ ]”) values but…
any user NH3 cal is retained
MOd ~ CAL appear on the upper or lower display for the upper or lower channel. CONF is for global setup.
All entries must be followed by pressing the ENT key.
Default values shown in square parentheses.
Table 1: Menu Tree for NH
3
5250