ECM NH3 5250 Скачать руководство пользователя страница 1

 

 
 
 
 
 
 
 
 
 
 
 
 

NH

3

 5250 

Single/Dual NH

3

 Analyzer 

 

 

 
 

Instruction Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

  

2/25/15 

 

Содержание NH3 5250

Страница 1: ...NH3 5250 Single Dual NH3 Analyzer Instruction Manual 2 25 15...

Страница 2: ...ll Rights Reserved No part of this manual may be photocopied or reproduced in any form without prior written consent from ECM ENGINE CONTROL AND MONITORING Information and specifications subject to ch...

Страница 3: ...e Setup Option AVG SKEW 19 CONF Configure Setup Option LEdS 1V4V CAN LOCK FACT 20 Specifications and Limits 22 Measurements and Accuracies 22 Sensor Limits and Specifications 22 Output Specifications...

Страница 4: ......

Страница 5: ...AC1 operation It is important to realize that when in the exhaust of a running engine the NH3 sensor is seeing H2O as just another gas Therefore it will report wet NH3 ppm numbers Classical gas analys...

Страница 6: ...e 1 m 10 02 5 Eurofast 12 mm Cable 4 m 09 01 6 Eurofast 12 mm Cable 2 m 09 02 7 Flexi Eurofast 12mm Cable 0 3 m 3 required 09 04 8 Eurofast T 4 required 09 05 9 Eurofast Termination Resistor 3 require...

Страница 7: ...rofast T 09 05 7 Boss Plug for NH3 sensor 12 02 Optional Items 1 Ceramic Sensor Cable 2m 10 03 2 Ceramic Sensor Cable 3m 10 37 3 Eurofast cable 10m 09 03 10 4 AC DC Power Supply Universal 24VDC 4 2A 0...

Страница 8: ...5250s cabling and sensor s on a stopped engine it is best to think out your moves before you make them Route and cable tie all cables away from hot moving sharp or high voltage spark objects Take into...

Страница 9: ...dules total can exist on the same EIB The EIB cable tees and termination resistors are industry standard Eurofast 12 mm The EIB can be extended to a length of 100 m The NH3 5250 can be turned on and o...

Страница 10: ...6 Power Entry Connect Connect Display Head Figure 1 NH3 5250 with Power Entry at Module End Module EIB Connector CAN EIB with Power Entry at Module End NH3 Sensor...

Страница 11: ...7 Power Entry EIB Connector CAN EIB with Power Entry at Display Head End Module NH3 Sensor Figure 2 NH3 5250 with Power Entry at Display Head End Connect Display Head...

Страница 12: ...fast 12 mm Cable P N 09 02 2 m Eurofast 12 mm Cable P N 11 16 DC Power Cable Banana Plugs shown or P N 11 15 Spades P N 04 01 AC DC Power Supply Universal 24 V P N 02 12 NH3CAN Module P N 01 10 NH3 52...

Страница 13: ...3 01 Manuals and Configuration Tool P N 09 04 0 3 m Flexi Eurofast Cable P N 09 05 Eurofast T P N 09 04 Eurofast Termination Resistor P N 12 01 19 Rackmount Panel CAN 500 kHz Broadcast P N 01 10 NH3 5...

Страница 14: ...10 Figure 5 Part Numbers of Components near Module P N 02 12 NH3CAN Module P N 10 02 1 m Ceramic Sensor Cable or P N 10 03 2 m or P N 10 37 3 m P N 06 07 NH3 Sensor...

Страница 15: ...sensor Mount where condensed material will not collect on the sensor ex if the section of exhaust pipe where the sensor is to be mounted is parallel to the ground the sensor should be mounted on the...

Страница 16: ...e list of parameters in Table 2 The and keys select which of the eight parameters are displayed unless the display is LOCKed see below While in RUN mode pressing the ENT key will toggle between the an...

Страница 17: ...r display parameter P10 VSW P11 lower channel Program lower display parameter P11 VH P12 lower channel Program lower display parameter P12 VS P13 lower channel Program lower display parameter P13 P P1...

Страница 18: ...ilter for NH3 and one for pressure See CAL Setup Option AVG Suboption for more information Parameter information from the module assigned to the upper channel can be sent to analog outputs 1 2 and 3 P...

Страница 19: ...Temperature of the module circuit board deg C C1R Cell 1 raw bits bits C2R Cell 2 raw bits bits ERFL Module error flags unsigned long format ERCd ECM CANOpen Error Code unsigned integer PR10 10 bit P...

Страница 20: ...h use NH3 sensors can age requiring recalibration to maintain measurement accuracy Recalibration can be performed by the user or by sending the sensor back to ECM The NH3 ZERO and SPAN functions are f...

Страница 21: ...be problematic 4 For the case of using the exhaust of an engine to span the NH3 sensor you must know the wet NH3 concentration from another instrument 5 Press the SYS key until MOd appears 6 Press th...

Страница 22: ...18 Figure 6 Model Gas Calibration Apparatus...

Страница 23: ...time t 5ms These user programmable filters range from 0 001 heavy averaging to 1 000 no averaging Parametert 5ms the parameter value at time t 5ms ParameterAveraget the parameter average at time t Th...

Страница 24: ...ead for CAN communication Depending on where the display head appears in your CAN bus the termination resistor may have to be present or removed The CAN data communicated is 1 What is being sent to an...

Страница 25: ...egers that refer to those listed in Appendix C The error codes are transmitted on the CAN bus least significant byte first Intel format The auxiliary code is the countdown number appearing on the chan...

Страница 26: ...e information Sensor Limits and Specifications NH3 Sensor Maximum Exhaust Temperature 450 C 842 F Maximum allowable levels of fuel Impurities Lead 0 012 gm gal 0 003 gm ltr Phosphorous 0 0008 gm gal 0...

Страница 27: ...be Metric Pressure Sensor Tubing Note Stainless steel end of tubing towards engine Teflon end towards pressure sensor Mating Thread with Engine NPT USA or ISO tapered Metric Tubing Assembled Length 19...

Страница 28: ...Impedance 2 66 k Bits Resolution 12 bits Update Rate 5 ms Isolation Electrically isolated from power supply ground All analog output grounds common CAN Protocol Broadcast Broadcast Rate Programmable...

Страница 29: ...case is connected to power ground via a 2 15 k resistor Key on Signal ON Voltage Level 2 7 to 32 VDC Current Draw 100 A Environment Display Head 40 to 85 C 100 humidity non condensing display head is...

Страница 30: ...sor no cables 02 05 appsCAN just module no cables 02 06 baroCAN just module no sensors no cables 02 07 NOxCAN T for T sensor just module no sensor no cables 02 08 LambdaCANp just module no sensor no c...

Страница 31: ...ic 07 03 Pressure Type P 0 75 psia 1 4 USA 07 04 Pressure Type P 0 517 kPa 6mm Metric 07 05 Pressure Type KP 0 75 psia 1 4 USA 07 06 Pressure Type KP 0 517 kPa 6mm Metric 07 07 RH Humidity Sensor 1 4...

Страница 32: ...r to use P N 2400E 1 sensor CPC with LCAN 10 16 Adapter to use P N 2400E 1S sensor Fischer with LCAN 10 17 Adapter to use P N 1001A 2 Deutsch with LCAN 10 21 Module Y Cable for all except Lp C and bCA...

Страница 33: ...Box to Hub Springy Cable 1m relaxed 2m stretched 11 28 Male Eurofast to DB9F 11 29 Simulator Power Cable 11 30 Simulator LSU4 9 Adapter Cable 11 31 Lemo to Eurofast Adapter Cable for LCANc 11 32 M F...

Страница 34: ...1 5mm male to 1 4 NPT female Plug 12 30 Carrying Case Medium 12 31 Alum Sensor Mounting Block 20mm 18mm not for Type T NOx 12 32 Small Alum Sensor Mounting Block 20mm 18mm not Type T 12 33 Pressure Li...

Страница 35: ...4 NPT Tap 14 04 1 4 ISO Tapered Tap 14 05 Antiseize 14 06 Metal Brush 14 07 Lambda Sensor Calibration System 14 08 20mmx1 5mm Bottoming Tap 14 09 Filler Bottle 14 10 Cupric Sulfate 3gm to add to 150cc...

Страница 36: ...ule must be properly configured in EIB mode or Stand alone mode depending on how it will be used To convert from one mode to the other requires software reprogramming of the lambda module followed by...

Страница 37: ...t the Configuration Tool software Click on the Module tab Select the CAN adapter being used Then start the communication 3 Click on the Set to EIB Mode Wait for Done Message Stop communication and exi...

Страница 38: ...off the end of the module Use an 18mm socket without the wrench 5 Release the two tangs at each side of the module 6 Slide the PCB out Remove the jumper from JP4 You can hang it on one pin of JP4 whe...

Страница 39: ...and can be on the EIB with a display To convert a module from EIB to Stand alone Mode The process is similar to the previously described procedure Note that in EIB mode the module will not show up in...

Страница 40: ...cted Bad NH3 cable or sensor 0023 Pulse Red 2x 2s CRC16 error Bad NH3 cable or sensor 0024 Pulse Red 2x 2s Invalid NH3 sensor memory chip parameter Wrong sensor 0025 Pulse Red 2x 2s Non compatible NH3...

Страница 41: ...Od is displayed 2 Press until CONF is displayed Then press ENT 3 Press until LOCK is displayed Then press ENT 4 50 will be displayed Press until 60 is displayed Then press ENT Display is now LOCKed To...

Страница 42: ...xclusive checked start the Configuration Tool select the Analyzers tab select the CAN Adapter leave Exclusive checked and then press the start button Status should change to Port Opened Producing a db...

Страница 43: ...ration Tool 3 Each analyzer s serial number will appear in the Device window list open window to see all present after its message format has been received by the Configuration Tool When an analyzer s...

Страница 44: ...40 Logging Data Analyzers whose serial numbers are in the Device window list can be data logged Press the Log Data button and follow the instructions Data is saved in csv format...

Страница 45: ...Create a new Database In the Database menu select New Give your database a name i e a folder name In INCA a Database means the current working directory Each project is created in a unique directory W...

Страница 46: ...42 5 Configure the hardware Click on the icon for the workspace you created in step 3 Open the Hardware Configuration icon under the section text 6 Hardware A hardware configuration window will open...

Страница 47: ...s example we are using an ETAS ES591 1 Expand the selection tree by clicking the next to the hardware device model Expand the CAN selection and select CAN Monitoring Click OK 7 Associate the dbc When...

Страница 48: ...ion Another window will pop up to confirm the device to connect to Click OK 9 Open an Experiment Environment Click on the Experiment Environment button on the upper tool bar to open an Experiment Envi...

Страница 49: ...displayed graphs charts gauges numeric etc When complete click OK We have left all configurations at default for this example 12 A new sub window will be added to the Experiment Environment You do not...

Страница 50: ...stopped To begin CAN monitoring click on the Start Visualization icon blue triangle on the left hand tool bar To stop CAN monitoring click the Stop Measuring icon black square on the left hand tool b...

Страница 51: ...hardware CAN interface can be used to read LambdaCAN data Hardware Setup A typical hardware configuration is shown in Figure 1 In this example a Kvaser Leaf Light CAN USB adapter is used Other support...

Страница 52: ...sor connector is visible green during normal operation flashing red without sensor attached 2 Run ECM Configuration Tool software and select the Modules tab or the Analyzers tab if connecting to 5200...

Страница 53: ...Configuration Tool is used to describe the format of the information available to VISION To setup a CANMonitor in ATI VISION 1 Run ATI VISION and open an existing Project File or create a new one by...

Страница 54: ...50 3 Add a physical hardware device by clicking Device Add Device and select Kvaser CAN Channel 4 Select a CANMonitor device by again clicking Device Add Device and select CANMonitor...

Страница 55: ...or by clicking Device Add CAN Database and browsing to the previously created dbc file 6 Enable the hardware by clicking Project Online The status of all of the devices should now show a Status of Onl...

Страница 56: ...52 7 To view data create a new Screen File and add a Control Click File New Screen File 8 Select Object Add Control Gauge...

Страница 57: ...ct Data Items window open the CANMonitor file tree to view all of the available signals Here the O2 from Node 0x10 has been selected Click OK to add the Data Item to the Control 10 Data should be visi...

Страница 58: ...ess for purpose whether express implied or arising by operation of law trade usage or course of dealing are hereby disclaimed The warranty is void if a module or the display head is opened LIMITATION...

Страница 59: ...lyzer AFM1540 Lambda Module AFM1600 Lambda and O2 Analyzer DIS1000 Display Head To which this declaration relates are in conformity with the essential requirements of the following standards EN61326 1...

Страница 60: ...56...

Страница 61: ......

Страница 62: ...Los Altos CA 94023 0040 USA 408 734 3433 Fax 408 734 3432 www ecm co com...