Instruction Manual MM850481 ed. 03a
32
x
Use the [
S
] and [
T
] keys to move the cursor symbol to “TIGHTNESS TEST” option.
x
Press the [
ENTER
] key to select the option. Press [
ESCAPE
] (F2) to return to the previous menu.
SELECT TEST
0.3 hPa
Parameters
Test Type : A
START TEST
ESCAPE
–
ZERO
x
Select “Parameters” option
PREFERENCES
Gas types : City
Net. Vol. 0.0
Tot. Vol. 0.0
Test Gas: Air
ESCAPE
–
NEXT
x
Set the follow parameters: Gas type (“City” or “Natural”) , Net. Vol.: (Total volume for Gas Network), Tot. Vol. (Internal
volume for Gas Flow Totalizer), Test Gas (“Air” or “Gas”).
x
Press Next to set Bar Press (Barometric Pressure).
x
Press
[
ESCAPE
] to return to the "SELECT TEST" page
x
Use the [
S
] and [
T
] keys to move symbol on the Test Types A
x
Select START TEST to start the procedure
P 1:
228.6 hPa
P 2: 228.7 hPa
ǻ
P: 0.1 hPa
Test A: 40s
ESCAPE
–
NEXT
The instrument will display the initial pressure to the P1 input and the final pressure P2 , as third parameter
There is the
ǻ
P, this is a result test that will come shows after the countdown (60 seconds) will ends.
Press
[
NEXT
] to display the following page
Suitability
Test Type: A
Disp. Found: 0.000
Disp. Corr: 0.000
Suitability: Yes
ESCAPE
–
Press the [
] button to print the report