20
|
P a g e
E850 E678 Instructions |
current as of May 2015 | Version 3
All information supplied by
Ecco Stove
®
is a trade mark of Landy Vent UK Limited copyright©EccoStove2015
Ecco Stove
| Foster House
| 2 Redditch Road,
Studley,
B80 7AX, United Kingdom
T
| +44 (0)1527 857 814
E
W
| www.eccostove.com
Patent pending USA, Canada, Europe & Russia | UK Patent nos: 2467433 & 2498883
L.
FLUEING.
The stove may be connected with a 150mm stove pipe to the flue it will
operate on SEE SECTION 19 (FLUE CONNECTIONS). The connecting stove pipe
pushes into the flue outlet. Fire cement or rope may be used.
M.
It will be necessary to beat the trims into shape for an improved fit to reduce
gaps as each piece moulds differently with each appliance.
CAUTION ONLY A RUBBER MALLETT MUST BE USED.
THE STOVE MAY NOW BE LIT
23.
MODEL 850
TECHNICAL HEATING APPLIANCE BS13240 SLOW HEAT RELEASE APPLIANCE BS15250
a)
Outputs:
nominated output 11.5kw
Thermal output 134 MJ
Nett efficiency 79.1%
Efficiency 85.3%
Gross efficiency 73%
CO
.24%
Space heating 7500 cu ft / 212 cu metres
b)
Weight: Complete appliance = 800 kg; The Ecco Stove must be installed onto a structural hearth
capable of bearing this weight.
c)
Air Supply – UK 35.75 cm sq.: outside UK to those countries local requirements. Vents to be
fitted to outside and positioned such that they are not liable to block. Additional ventilation
requirement may be needed if the stove is operated simultaneously with other heating
appliances. It is important to ensure adequate supply of combustion and ventilation air.
d)
Extractor fans: No extractor fans are to be fitted in the same room as the Ecco Stove.
e)
Fire draught: Minimum cold flue draught to be .04 inches water gauge, maximum .06 inches
water gauge.
f)
Flue gas mass flow: 11.4 gs
g)
Flue gas temperature: Average 222°C at nominal output.
h)
Flue outlet: 150mm top exit (Dampers may be necessary if the flue draught is in excess of 0.4”
water gauge). This pipe must include a soot door/access plate within 200 mm of the stoves top.
i)
Heat energy stored 134 MJ
j)
Co-concentration at 13% oxygen = 0.34%. Excessive flue draught may remove too much heat
from the Ecco Stove on slow combustion. A damper may be fitted into the flue pipe off the