• Plate Heat Exchanger
Subject
Descrip
�
on
Part’s Function
1- The component that transfers the heat from the hot water from the main heat exchanger
to the domestic water installation in order to meet domestic water demands.
2- The water circulation is maintained through this componen (internal by-pass) when all
radiator valves are closed.
Impact in Case of Malfunction
1- In case of partial or complete blockage, domestic water does not heat up or continuously
overheats.
2- The central heating circuit overheats as the internal by-pass function does not work.
3- The pressure in the central heating system constantly increases (the domestic water
enters the central heating circuit due to puncture in the plate heat exchanger).
Main Associated Error Codes
E03, F07, E16, E17,E80, F40
Error Diagnostics and Test Method
1- Visually inspect for leakage from the plate heat exchanger to the external environment.
2- Check whether the central heating circuit pressure changes excessively by turning on the
domestic water.
Maintenance Requirement
Internal Cleaning of The Plate
Maintenance Descrip
�
on
Maintenance Method
Internal Cleaning of The Plate
1- Remove the plate heat exchanger.
2- Fill the plate heat exchanger holes with decalcifier (HN03) and wait for 10 minutes.
3- Pour out the decalcifier and wash the inside of the plate heat exchanger with
water.
Table 1
4
65
Содержание CONFEO PREMIX P 14 HM
Страница 1: ...SERVICE MANUAL CONFEO PREMIX CONDENSING BOILER CONFEO PREMIX P 14 20 24 28 30 35 HM HCH HST...
Страница 24: ...12 ELECTRICAL DIAGRAM Figure 15 24...
Страница 34: ...Low Voltage Removing installing the pump cable FAN PWM CABLE Figure 39 Figure 40 34...
Страница 52: ...Figure 76 Figure 77 52...
Страница 83: ......