Parameter Descriptions
P00:
Device type selection (HM/HM+Solar/HST/HST+Solar/HCH)
P01:
Gas type selection (Natural/LPG)
P03:
Water filling selection (inactive/active/automatic)
P26:
When the CH set temperature reaches the closing value (hysteresis off), the boiler stops
burning. Even if the temperature drops below the device opening value (hysteresis on), the boiler
does not reac
-
tivate until the time set by this parameter has expired. If the boiler has complaints of
frequent activation, the time in this parameter can be increased.
P35:
OTC curve selection is based on the temperature difference between the exterior temperature
and the set temperature set by the user according to the selected curve slope and the combi
boiler starts to run when it rises above that temperature difference.
P38:
Hydroblock selection (Composite/Brass)
P39:
Device capacity and model selection. Only V1 versions will be available.
P40:
Determines the heating system type. (Radiator/floor heating)
P41:
This is the parameter that determines the temperature at which the device starts to run in
ECO mode.
- Eco Mode Hysteresis ON Set Value:
- P41: The factory-set value is 1. Example: When
the CH set value is set to 30 °C, there is no flame
before the boiler return water temperature sensor
reaches 27 °C.
The value that can be set by the service is 0.
If the user wishes to consume even less fuel in
ECO mode, it can be activated by the service.
P41
1
0
Set Value
CH Return Water
Temperature
CH Return Water
Temperature
30
27
22
35
27
22
40
31
26
45
34
29
50
36
31
55
40
35
60
44
39
65
47
42
70
51
46
75
53
48
80
57
52
Table
4
10
Содержание CONFEO PREMIX P 14 HM
Страница 1: ...SERVICE MANUAL CONFEO PREMIX CONDENSING BOILER CONFEO PREMIX P 14 20 24 28 30 35 HM HCH HST...
Страница 24: ...12 ELECTRICAL DIAGRAM Figure 15 24...
Страница 34: ...Low Voltage Removing installing the pump cable FAN PWM CABLE Figure 39 Figure 40 34...
Страница 52: ...Figure 76 Figure 77 52...
Страница 83: ......