Remove the ignition-ionization screws using an Allen wrench.
Torque: 1 ± 0.2 Nm (Torx 4 mm)
Remove the 4 cover screws of the heat exchanger. When removing and installing the heat exchanger
cover, perform the operations according to the order written on the cover.
Torque: 5 ± 0.5
Figure 71
Figure 72
Figure 73