![Ebyte E180-Z5812SX Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/ebyte/e180-z5812sx/e180-z5812sx_manual_3872507022.webp)
Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-Z5812SX User Manual
Copyright ©2012–2021, Chengdu Ebyte Electronic Technology Co., Ltd.
21
6.6.5 Network PAN_ID
Command format for Read:
Command Format
Command Example
Send: FE 02 03 FF
Reply: FB 03 pan_id
Send: FE 02 03 FF
Reply: FB 03 FE 5B
Command format for Configuration:
Command Format
Command Example
Send: FD 02 03 pan_id FF
Reply: FA 03
Send: FD 02 03 FE 5B FF
Reply: FA 03
pan_id:
0x0000
~
0xFFFE fixed network PAN_ID
0xFFFF random network PAN_ID
Note: If the coordinator is configured as 0xFFFF, then PANID is randomly selected to establish a network. Terminals, routing,
etc. can be configured with 0xFFFF to join any PANID network. PANID parameters need to be configured before joining the
network.
6.6.6 Network Short Address:
Command format for Read:
Command Format
Command Example
Send: FE 02 05 FF
Reply: FB 05 Short_Addr
Send: FE 02 05 FF
Reply: FB 05 F6 FA
Short_Addr:2 Byte, Address randomly assigned by the coordinator
6.6.7 MAC Address
Command format for Read:
Command Format
Command Example
Send: FE 08 06 FF
Reply: FB 06 Mac_Addr
Send: FE 08 06 FF
Reply: FB 06 1F 1C 21 FE
FF 57 B4 14
Mac_Addr: 8 Byte