Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-Z5812SX User Manual
Copyright ©2012–2021, Chengdu Ebyte Electronic Technology Co., Ltd.
23
6.6.11Network Channel
Command format for Read:
Command Format
Command Example
Send: FE 01 0A FF
Reply: FB 0A channel
Send: FE 01 0A FF
Reply: FB 0A 0B
Command format for Configuration:
Command Format
Command Example
Send: FD 01 0A channel FF
Reply: FA 0A
Send: FD 01 0A 0B FF
Reply: FA 0A
channel: Channel range 0x0B(11)
~
0x1A(26) (default 11 channels), 0xFF means full channel scan.
The channel parameter needs to be configured before entering the network.
6.6.12 Transmitting Power
Command format for Read:
Command Format
Command Example
Send: FE 01 0B FF
Reply: FB 0B txpower
Send: FE 01 0B FF
Reply: FB 0B 0A
Command format for Configuration:
Command Format
Command Example
Send: FD 01 0B txpower FF
Reply: FA 0B
Send: FD 01 0B 0A FF
Reply: FA 0B
txpower: The transmit power level (00) needs to be configured before entering the network.
Note: The transmitting power subjects to the actual value.
Power Code
Target Power (dbm
)
Power Code
Target Power (dbm
)
00
11.76
06
10.33
01
11.66
07
10.04
02
11.31
08
9.73
03
11.09
09
9.38
04
11.76
0A
9.03
05
11.66