![Ebyte E180-Z5812SX Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/ebyte/e180-z5812sx/e180-z5812sx_manual_3872507013.webp)
Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-Z5812SX User Manual
Copyright ©2012–2021, Chengdu Ebyte Electronic Technology Co., Ltd.
12
6.1.5 UART_BAUD_RESET Details
The UART BAUD RESET pin is used to reset the baud rate of the device. It defaults to a high level after power-on. In any mode,
the module serial port parameters will be restored to the default 115200 and 8N1 if the pin is pulled down for more than 1000ms.
Pins
Interface
LINK
PC1
WAKE
PD3
AUX
PB5
ACK
PB1
UART_BAUD_RESET
PA1
6.2 Wireless remote configuration function
The module supports the remote configuration function, which is identified by the two-byte wireless
configuration ID by default as A8 8A. The user can modify the remote configuration ID of the module. When the
module receives the first two bytes of wireless air data as the wireless configuration ID, The module judges that the
data packet is a remote configuration command and executes the operation corresponding to the command. The
data packet will not be output through the serial port. The remote configuration of the dormant terminal needs to
wake up first.
6.3 Function Parameter Description
The module provides a wealth of configurable parameters, which can be used flexibly according to actual
application requirements to construct different forms of networks.
Configuration
Type
Code Range
Functions
PANID
Read/
write
0x0000
~
0xFFFF
PANID is the network identifier of ZIGBEE, used to determine the
identity of the network to which it belongs. The PANID of all devices in
the same network must be the same. When the terminal or router is
configured as 0xFFFF, it can join any network where the same channel
already exists.
Local
network
address
read
0x0000
~
0xFFFF
Used to distinguish each node in the network. Each device is in the same
network. The local network address must be unique. When not joining the
network, the network address of the device is 0xFFFF. After joining, the
device short address is assigned by the coordinator. The coordinator is
fixed as: 0x0000.
network
status
read
0
、
2
、
3
Indicates the network status of the current device, including no network,
has successfully joined the network, and there is no parent node.
Destination
network
address
Read/
write
0x0000
~
0xFFFF
The current device communication destination (short address) can be
switched at any time through configuration commands.
Local MAC
read
64bitMAC
The MAC address assigned by the network of this module cannot be